Ariston COMPACT M NET R32 Technical Instructions For Installation page 63

Table of Contents

Advertisement

Menu.
Sub-menu.
Parameter
1.
3
CH secondary heat source activation
1.
3.
0 CH aux heat source activation logic
1.
3.
1 Active resistance stages
1.
3.
2 ECO / COMFORT
1.
4
DHW secondary heat source activation
1.
4.
0 DHW aux heat source activation logic
1.
4.
1 Active resistance stages
1.
4.
2 Delay timer
1.
4.
3 Release integral threshold
1.
4.
4 Tank electric heater
1.
4.
6 DHW high priority temperature threshold
1.
5
Energy manager parameter 1
1.
5.
0 Min pressure
1.
5.
1 Warning pressure
1.
5.
2 Text for boiler disabling
1.
5.
3 Text for HP disabling
1.
5.
4 Hp disabling out temp DHW
1.
5.
5 External temperature correction
1.
5.
9 Filling pressure
1.
6
Water circulation
1.
6.
0 CH pump prerun time
1.
6.
1 Time for prerun new attempt
1.
6.
2 CH pump overrun
1.
6.
3 Pump speed control
1.
6.
4 Antifreeze HP circulator control
1.
7
CH
1.
7.
1 Boost Time
1.
7.
2 FlowT HP Offset
1.
8
Cool mode
1.
8.
0 Cooling mode activation
1.
8.
2 Cooling FlowT HP Offset
1.
9
Domestic hot water
1.
9.
0 DHW comfort setpoint temp.
1.
9.
1 DHW reduced setpoint temp.
Description
Default
Range - Value
0 = Heat integr. and backup
1
1 = HP failure backup
2
0 = Eco Plus
1 = Eco
2
2 = Average
3 = Comfort
4 = Comfort Plus
0 = Heat integr. and backup
0
1 = HP failure backup
0 = None
1 = 1 Stage
2
2 = 2 Stages
3 = 3 Stages
30 min
[10 -120]min
60°C*min
[15 -200]°C*min
0 = Absent
1 = Disabled
0
2 = Alone electric heater
3 = Auxiliary
20°C - Par. 1.9.0 DHW Comfort
20°C
Temperature
0.4 bar
[0.3 -0.4]bar
0.6 bar
[0.4 -0.8]bar
35°C
[Text for boiler disabling; 40]°C
-20°C
[-20;Text for HP disabling]°C
[-20;Hp disabling out temp
-20°C
DHW]°C
0°C
[-3; +3 ]°C
1.2 bar
[0.9 - 1.5]bar
30s
[30-255]s
90s
[0-100]s
3min
[0-16]min
0 = Low speed
2
1 = High speed
2 = Modulating
0 = Low speed
1
1 = Med speed
2 = High speed
16min
[0 - 60] min
0°C
[0 - 10]°C
0 = Provisioned - Not active
0
1 = Run
0°C
[-10 - 0]°C
55°C
[35 - 65] °C
[35 - DHW reduced setpoint
35°C
temp.]°C
Commissioning
Notes
63 / EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

3301721330172233017233301724

Table of Contents