Ariston COMPACT M NET R32 Technical Instructions For Installation page 32

Table of Contents

Advertisement

The cross-sectional size of the cables used must comply with the system power (see data plate).
The cross-sectional size of the power cables indicated in the table must be regarded as the minimum cross-sectional -size.
i
Prior to accessing the terminals, all the supply circuits must be disconnected.
OUTDOOR UNIT
Rated current / live
Maximum current / live
Thermal cut-out size
Residual-current circuit breaker
(RCCB) size
Surge current
Rated voltage
Permissible voltage fields
Cos phi
Power supply wiring
Communication cabling
The power supplies of the indoor and outdoor units must be connected respectively to a dedicated residual-current circuit break-
er (RCCB) with a minimum threshold of 30 mA. For units equipped with an inverter (outdoor unit), we recommend using type B
residual-current devices for 3 ph power supplies and type B or F devices (depending on the electrical system to which they are
connected) for 1 ph power supplies. For units lacking an inverter (indoor unit), a type A residual-current device will suffice. The type
of connection must nonetheless be made in a workmanlike manner by qualified personnel in order to comply with the national
regulations in force.
Main power supply table.
INDOOR UNIT
Power supply
Permissible voltage fields
Nominal absorbed power
Maximum current
Thermal cut-out
Residual-current circuit breaker
(RCCB) size
Power supply wiring
EDF, AFR, PV signal cabling
Note: in making the connection between the communication cable from the indoor unit to the outdoor unit, use a shielded cable
to prevent interference problems.
32 / EN
35 M
A
11,0
A
11,7
A
C-16
mA
A
V
230
V
216-
243
Reference
Cable min. cross-sec-
3G4
tional size
Max. diameter [mm]
14
Recommended cable
3G4
cross-sectional size
Reference
Cable cross-sectional
size
Max. length
NIMBUS FS M R32 - NIMBUS
V - ph - Hz
230 - 1 -50
V
196 ÷ 253
kW
A
A
mA
Reference
Cable min. cross-sec-
tional size
Max. diameter [mm]
Recommended cable
cross-sectional size
Max. diameter [mm]
mm
2
NIMBUS EXT R32
50 M
80 M
80
M-T
13,5
20,0
7,6
14,3
21,3
8,1
C-20
C-32
C-13
F-30 / B-30
B-30
< 3
230
230
400
216-
216-
376-
243
243
424
> 0,9
H07RN-F
3G4
3G4
5G2,5
16,2
16,2
17
3G4
3G6
5G4
H05RN-F
3 x 0,75mm
50 m
FS M 2Z R32
400 - 3 -50
340 ÷ 440
4
4
19,1
9,6
C-25
C-16
A-30
H07RN-F
3G4
5G2,5
16,2
17
3G4
5G4
16,2
19,9
H05RN-F 2 x 0,75 mm
2
- H07RN-F 2 x 1,0 mm
Electrical connections
120
120
150
150
M
M-T
M
M-T
22,5
7,8
26,9
9,41
23,9
8,3
28,7
10,0
C-32
C-13
C-32
C-13
F-30 /
B-30
F-30 /
B-30
B-30
B-30
230
400
230
400
216-
376-
216-
376-
243
424
243
424
3G6
5G2,5
3G6
5G2,5
17
17
18
18
3G6
5G4
3G6
5G4
2
NIMBUS FS-L M R32 - NIM-
BUS FS-L M 2Z R32
230 - 1 -50
400 - 3 -50
196 ÷ 253
340 ÷ 440
6
6
30
10
C-32
C-16
3G6
5G2,5
18
17
3G6
5G4
18
19,9
2