[31] Meter output (2/2)
Communi
Title
cation No
0690

AM/FM output parameter for adjustment −

0697
  
  [32] Control panel parameters
Communi
Title
Function
cation No

0700
Prohibition of parameter setting 0: Allowed,1: Prohibited
0701
Current/voltage display mode 0: [%], 1: [A] or [V]


0702
Frequency free unit magnification 0.00: OFF, 0.01∼200.0
0703
Decimal place number of frequency 0: 1 [Hz], 1: 0.1 [Hz], 2: 0.01 [Hz]


0704
Decimal place number of acc/dec time 0: 1[s], 1: 0.1[s], 2: 0.01[s]
Prohibition of user parameter

0709
initialization at type form initialization

0710
Monitor display mode setting 0∼29
0711
Status monitor #1 display mode 0∼29


0712
Status monitor #2 display mode 0∼29
0713
Status monitor #3 display mode 0∼29


0714
Status monitor #4 display mode 0∼29
0720
Selection of panel V/f1, 2, 3 or 4


0721
Panel stop pattern
0722
Panel reset function


0723
Panel torque limit
0724
Panel PID control OFF

0725
Panel torque reference


0726
Panel synchronized torque bias -250∼250 [%]
0727
Panel tension torque bias


0728
Panel load sharing gain
0729
Panel over-ride multiplication gain -100∼100 [%]


0730
Panel operation prohibition
Function
Adjustment range
Adjustment range
0: Allowed
1: Prohibited
1: V/f #1, 2: V/f #2, 3: V/f #3, 4: V/f #4
0: Deceleration stop,1: Coast stop
0: Disabled, 1: Enabled
1∼4
0: ON, 1: OFF
0∼250 [%]
-250∼250 [%]
0∼250 [%]
0: All key operations prohibited
+1: Panel frequency setting enabled
+2: Parameter reading/writing enabled
+4: Monitor display operation enabled
+8: Panel drive operation enabled
(+16: no function)
+32: Emergency stop operation enabled
63: Default mode (all key operation enabled)
Sensorless vector/vector with sensor (●valid, −:invalid)
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
0
Enabled
●/●
0
Enabled
●/●
0.01/0.01
0.00
Enabled
●/●
1
Enabled
●/●
1
Enabled
●/●
0
Enabled
●/●
0
Enabled
●/●
1
Enabled
●/●
2
Enabled
●/●
3
Enabled
●/●
4
Enabled
●/●
1
Enabled
0
Disabled
●/●
1
Disabled
●/●
1
Enabled
●/●
0
Enabled
●/●
1/0.01
0
Enabled
1/0.01
0
Enabled
●/●
1/0.01
0
Enabled
1/0.01
100
Enabled
1/0.01
0
Enabled
●/●
63
Disabled
●/●
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
●/●
−/●
6.29.1
6.29.2
●/●
−/●
●/●
−/●
6.29.3
6.29.4
●/●
−/●
●/●
−/●
6.29.4
●/●
―/●
●/●
−/●
8.1
8.1
●/●
−/●
●/●
−/●
8.1
8.1
●/●
−/●
●/●
−/●
8.1
6.29.6
●/●
−/●
6.29.7
6.29.8
●/●
−/●
●/●
−/●
6.29.9
6.29.10
6.29.11
●/●
−/●
6.21.4
6.21.4
●/●
●/●
6.21.4
6.29.13
●/●
−/●
6.29.14