[7] Speed/torque reference gain/bias setup (1/2)
Communi
Title
Function
cation No
0200
Reference priority selection
0201
VI/II reference point #1
0202
VI/II reference point #1 frequency 0.0∼ [Hz]
0203
VI/II reference point #2
0204
VI/II reference point #2 frequency 0.0∼ [Hz]
0205
VI/II reference point #1 rate
0206
VI/II reference point #2 rate
0207
Speed setting mode selection #2 Same as (1 to 11)
0208
/ switching frequency 0.1∼ [Hz]
0209
Analog input filter
0210
RR reference point #1
0211
RR reference point #1 frequency 0.0∼ [Hz]
0212
RR reference point #2
0213
RR reference point #2 frequency 0.0∼ [Hz]
0214
RR reference point #1 rate
0215
RR reference point #2 rate
0216
RX reference point #1
0217
RX reference point #1 frequency -∼ [Hz] (*3)
0218
RX reference point #2
0219
RX reference point #2 frequency -∼ [Hz] (*3)
0220
RX reference point #1 rate
0221
RX reference point #2 rate
0222
RX2 reference point #1
0223
RX2 reference point #1 frequency -∼ [Hz] (*3)
0224
RX2 reference point #2
0225
RX2 reference point #2 frequency -∼ [Hz] (*3)
0226
RX2 reference point #1 rate
0227
RX2 reference point #2 rate
(*1): When setup frequency(signal set up by ) is or more, signal set up by is accepted, When setup frequency is lower than , the inverter runs under the signal of .
(*2): When setup frequency(signal set up by ) is or more, signal set up by is accepted, When setup frequency is lower than , the inverter runs under the signal of .
(*3): Adjustment range is -327.68∼327.67 [Hz] in case of 16-bit access.
※(Reference section): Refer to the inverter's individual manual.
Adjustment range
0:
1:
2: priority (*1)
3: priority (*2)
4: / switching
0∼100 [%]
0∼100 [%]
-250∼250 [%] (For torque control, etc.)
-250∼250 [%] (For torque control, etc.)
0(Disabled) to 3(Max. filter capacity)
0∼100 [%]
0∼100 [%]
0∼250 [%] (For torque control, etc.)
0∼250 [%] (For torque control, etc.)
-100∼100 [%]
-100∼100 [%]
0∼250 [%] (For torque control, etc.)
0∼250 [%] (For torque control, etc.)
-100∼100 [%]
-100∼100 [%]
-250∼250 [%] (For torque control, etc.)
-250∼250 [%] (For torque control, etc.)
Sensorless vector/vector with sensor (●valid, −:invalid)
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
−
0
Enabled
●/●
1/0.01
20.0
Enabled
●/●
0.01/0.01
0. 0
Enabled
●/●
1/0.01
100
Enabled
●/●
0.01/0.01
80.0
Enabled
●/●
1/0.01
0
Enabled
●/●
1/0.01
100
Enabled
●/●
1
Enabled
−
●/●
0.01/0.01
1.0
Enabled
●/●
0
Enabled
−
●/●
1/0.01
0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
1/0.01
100
Enabled
●/●
0.01/0.01
80.0
Enabled
●/●
1/0.01
0
Enabled
●/●
1/0.01
100
Enabled
●/●
1/0.01
0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
1/0.01
100
Enabled
●/●
0.01/0.01
80.0
Enabled
●/●
1/0.01
0
Enabled
●/●
1/0.01
100
Enabled
●/●
1/0.01
0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
1/0.01
100
Enabled
●/●
0.01/0.01
80.0
Enabled
●/●
1/0.01
0
Enabled
●/●
1/0.01
100
Enabled
●/●
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
−
−
●
6.6.1
7.3.2
●/●
−
●
●/●
−
●
7.3.2
7.3.2
●/●
−
●
−
−
●
7.3.2
6.21.1
●/●
−
−
●/●
−
−
6.21.1
6.61
−
−
●
−
−
●
6.6.1
7.2.4
●/●
−
●
●/●
−
●
7.3.1
7.3.1
−
−
●
●/●
−
●
7.3.1
7.3.1
−
−
●
●/●
−
−
6.21.1
6.21.1
●/●
−
−
●/●
−
●
7.3.3
7.3.3
−
−
●
●/●
−
●
7.3.3
7.3.3
−
−
●
●/●
−
−
6.21.1
6.21.1
●/●
−
−
●/●
−
●
※
−
−
●
※
●/●
−
●
※
−
−
●
※
●/●
−
●
※
●/●
−
●
※