Toshiba TOSVERT VF-P7 Instruction Manual page 215

Inverter for fan and pump applications
Hide thumbs Also See for TOSVERT VF-P7:
Table of Contents

Advertisement

[24] Torque limit
Communi
Title
Function
cation No
0440
Selection of power running torque limit #1


0441
Power running torque limit #1 0∼249.9 [%], 250: Invalid
0442
Selection of regenerative torque limit #1


0443
Regenerative torque limit #1
0444
Power running torque limit #2 0∼249.9 [%], 250: Invalid


0445
Regenerative torque limit #2
0446
Power running torque limit #3 0∼249.9 [%], 250: Invalid


0447
Regenerative torque limit #3
0448
Power running torque limit #4 0∼249.9 [%], 250: Invalid


0449
Regenerative torque limit #4

0450
Torque limit mode (polarity)

0451
Torque limit mode
Continuous stall trip detection

0452
time during power running
0453
Stall prevention during regeneration

[25] Speed/torque reference gain/bias setup #2(1/2)
Communi
Title
Function
cation No

0454
Current differential gain
High-speed magnetic field
0455

control gain
High-speed magnetic field
0456
rate-of-change limitation

gain
0470
VI/II reference bias


0471
VI/II reference gain
0472
RR reference bias


0473
RR reference gain
0474
RX reference bias


0475
RX reference gain
0476
RX2 reference bias


0477
RX2 reference gain
0480
Exciting strengthening coefficient 0∼255


0481
Over-excitation cooperation
Modulation rate control

0482
margin (current control)
Adjustment range
1 :VI/II, 2: RR, 3: RX, 4: RX2, 5: 
1 :VI/II, 2: RR, 3: RX, 4: RX2, 5: 
0∼249.9 [%], 250: Invalid
0∼249.9 [%], 250: Invalid
0∼249.9 [%], 250: Invalid
0∼249.9 [%], 250: Invalid
0: Power-running/regenerative torque limit
1: Positive/negative torque limit
0: Standard, 1: without speed cooperation
0.0∼1.0 [s]
0: Stall
1: Stall is prevented
Adjustment range
0.00∼327.6
1.64∼327.6
1.64∼327.6
0∼255
0∼255
0∼255
0∼255
0∼255
0∼255
0∼255
0∼255
0: Enabled, 1: Applied by  setting
80.0∼300.0 [%]
Sensorless vector/vector with sensor (●valid, −:invalid)
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
5
Enabled
●/●
0.1/0.01
250.0
Enabled
●/●
5
Enabled
●/●
0.1/0.01
250.0
Enabled
●/●
0.1/0.01
250.0
Enabled
●/●
0.1/0.01
250.0
Enabled
●/●
0.1/0.01
250.0
Enabled
●/●
0.1/0.01
250.0
Enabled
●/●
0.1/0.01
250.0
Enabled
●/●
0.1/0.01
250.0
Enabled
●/●
0
Disabled
●/●
0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0
Enabled
●/●
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
0.01/0.01
123.0
Enabled
●/−
0.01/0.01
16.38
Enabled
●/●
0.01/0.01
163.8
Enabled
●/●
1/1
99
Enabled
●/●
1/1
142
Enabled
●/●
1/1
100
Enabled
●/●
1/1
164
Enabled
●/●
1/1
67
Enabled
●/●
1/1
128
Enabled
●/●
1/1
67
Enabled
●/●
1/1
128
Enabled
●/●
1/1
64
Enabled
●/―
0
Enabled
●/―
0.1/0.01
90.0
Enabled
●/●
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
6.22
●/●
−/●
●/●
−/●
6.22
6.22
●/●
−/●
●/●
−/●
6.22
6.22
●/●
−/●
●/●
−/●
6.22
6.22
●/●
−/●
●/●
−/●
6.22
6.22
●/●
−/●
●/●
−/●
6.22
●/●
−/●
6.22
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
●/●
―/●
●/●
―/●
●/●
―/●
●/●
―/●
●/●
―/●
●/●
―/●
●/●
―/●
●/●
―/●
●/●
―/●
●/●
―/●
●/―
●/―
●/●
―/●