[27] Pattern run (2/2)
Communi
Title
Function
cation No
Preset-speed #1 operation
0570
continuation mode
0571
Preset-speed #2 operation continuation mode Ditto
0572
Preset-speed #3 operation continuation mode Ditto
0573
Preset-speed #4 operation continuation mode Ditto
0574
Preset-speed #5 operation continuation mode Ditto
0575
Preset-speed #6 operation continuation mode Ditto
0576
Preset-speed #7 operation continuation mode Ditto
0577
Preset-speed #8 operation continuation mode Ditto
0578
Preset-speed #9 operation continuation mode Ditto
0579
Preset-speed #10 operation continuation mode Ditto
0580
Preset-speed #11 operation continuation mode Ditto
0581
Preset-speed #12 operation continuation mode Ditto
0582
Preset-speed #13 operation continuation mode Ditto
0583
Preset-speed #14 operation continuation mode Ditto
0584
Preset-speed #15 operation continuation mode Ditto
0585
Preset-speed #1 operation time
0586
Preset-speed #2 operation time
0587
Preset-speed #3 operation time
0588
Preset-speed #4 operation time
0589
Preset-speed #5 operation time
0590
Preset-speed #6 operation time
0591
Preset-speed #7 operation time
0592
Preset-speed #8 operation time
0593
Preset-speed #9 operation time
0594
Preset-speed #10 operation time
0595
Preset-speed #11 operation time
0596
Preset-speed #12 operation time
0597
Preset-speed #13 operation time
0598
Preset-speed #14 operation time
0599
Preset-speed #15 operation time
Adjustment range
0: Operation time in second after start of operation
1: Operation time in minute after start of operation
2: Operation time in second after attainment of frequency
3: Operation time in minute after attainment of frequency
4: Infinite (continued until stop command is entered)
5: Continue until next step command
1∼8000 [s] / [min]
(The unit depends on )
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Sensorless vector/vector with sensor (●valid, −:invalid)
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
−
0
Disabled
●/●
0
Disabled
−
●/●
−
0
Disabled
●/●
0
Disabled
−
●/●
−
0
Disabled
●/●
0
Disabled
−
●/●
−
0
Disabled
●/●
−
0
Disabled
●/●
−
0
Disabled
●/●
−
0
Disabled
●/●
0
Disabled
−
●/●
−
0
Disabled
●/●
0
Disabled
−
●/●
−
0
Disabled
●/●
0
Disabled
−
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
−
−
●
6.24
6.24
−
−
●
−
−
●
6.24
6.24
−
−
●
−
−
●
6.24
6.24
−
−
●
−
−
●
6.24
−
−
●
6.24
−
−
●
6.24
−
−
●
6.24
6.24
−
−
●
−
−
●
6.24
6.24
−
−
●
−
−
●
6.24
6.24
−
−
●
6.24
−
−
●
−
−
●
6.24
6.24
−
−
●
−
−
●
6.24
6.24
−
−
●
−
−
●
6.24
6.24
−
−
●
−
−
●
6.24
6.24
−
−
●
6.24
−
−
●
6.24
−
−
●
6.24
−
−
●
−
−
●
6.24
6.24
−
−
●
−
−
●
6.24