[27] Pattern run (2/2)
Communi
Title
Function
cation No
Preset-speed #1 operation

0570
continuation mode
0571
Preset-speed #2 operation continuation mode Ditto


0572
Preset-speed #3 operation continuation mode Ditto
0573
Preset-speed #4 operation continuation mode Ditto


0574
Preset-speed #5 operation continuation mode Ditto
0575
Preset-speed #6 operation continuation mode Ditto


0576
Preset-speed #7 operation continuation mode Ditto

0577
Preset-speed #8 operation continuation mode Ditto

0578
Preset-speed #9 operation continuation mode Ditto

0579
Preset-speed #10 operation continuation mode Ditto
0580
Preset-speed #11 operation continuation mode Ditto


0581
Preset-speed #12 operation continuation mode Ditto
0582
Preset-speed #13 operation continuation mode Ditto


0583
Preset-speed #14 operation continuation mode Ditto
0584
Preset-speed #15 operation continuation mode Ditto

0585
Preset-speed #1 operation time


0586
Preset-speed #2 operation time
0587
Preset-speed #3 operation time


0588
Preset-speed #4 operation time
0589
Preset-speed #5 operation time


0590
Preset-speed #6 operation time
0591
Preset-speed #7 operation time


0592
Preset-speed #8 operation time
0593
Preset-speed #9 operation time

0594
Preset-speed #10 operation time

0595
Preset-speed #11 operation time

0596
Preset-speed #12 operation time


0597
Preset-speed #13 operation time
0598
Preset-speed #14 operation time


0599
Preset-speed #15 operation time
Adjustment range
0: Operation time in second after start of operation
1: Operation time in minute after start of operation
2: Operation time in second after attainment of frequency
3: Operation time in minute after attainment of frequency
4: Infinite (continued until stop command is entered)
5: Continue until next step command
1∼8000 [s] / [min]
(The unit depends on )
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Sensorless vector/vector with sensor (●valid, −:invalid)
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
0
Disabled
●/●
0
Disabled
●/●
0
Disabled
●/●
0
Disabled
●/●
0
Disabled
●/●
0
Disabled
●/●
0
Disabled
●/●
0
Disabled
●/●
0
Disabled
●/●
0
Disabled
●/●
0
Disabled
●/●
0
Disabled
●/●
0
Disabled
●/●
0
Disabled
●/●
0
Disabled
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
1/1
5
Enabled
●/●
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
6.24
6.24
6.24
6.24
6.24
6.24
6.24
6.24
6.24
6.24
6.24
6.24
6.24
6.24
6.24
6.24
6.24
6.24
6.24
6.24
6.24
6.24
6.24
6.24
6.24
6.24
6.24
6.24
6.24
6.24

Hide quick links: