1. Basic parameters (2/2)
Communi
Title
Function
cation No.
Forward/reverse selection
0008

(At panel control only)
0009
Acceleration time #1


0010
Deceleration time #1
0011
Maximum frequency


0012
Upper limit frequency
0013
Lower limit frequency


0014
Base frequency #1
Motor control mode

0015
selection
0016
Manual torque boost

Selection of electronic
thermal protection

0017
characteristics

0018
Preset-speed #1
0019
Preset-speed #2


0020
Preset-speed #3
0021
Preset-speed #4


0022
Preset-speed #5
0023
Preset-speed #6


0024
Preset-speed #7

Extended parameter

Automatic edit function

* Minimum setup unit is 0.1 in case of 16-bit access.   Sensorless vector/vector with sensor (
Adjustment range
0: Forward,
1: Reverse
0.1()∼6000 [s]
0.1()∼6000 [s]
30.0∼400.0 [Hz]
0.0∼ [Hz]
0.0∼ [Hz]
25.0 ∼400.0 [Hz]
0: Constant torque
1: Variable torque mode
2: Automatic torque boost
3: Sensorless vector control (speed)
4: Automatic torque boost + automatic energy-saving
5: Sensorless vector control (speed) + automatic energy-saving
6: V/f 5-points setting
7:Sensorless vector control (speed/torque switching)
8: PG feedback vector control (speed/torque switching)
9: PG feedback vector control (speed/position switching)
0∼30%
Overload
Setting
Overload stall
Type
protection
0
protect
not stall
1
Standard
protect
motor
2
not protect
not stall
3
not protect
4
protect
not stall
VF motor
5
protect
(special
6
not protect
not stall
motor)
7
not protect
∼ [Hz]
∼ [Hz]
∼ [Hz]
∼ [Hz]
∼ [Hz]
∼ [Hz]
∼ [Hz]
Setting of extended parameters listed on the
following pages
To search parameters different from default value
Min. unit (panel/
Default
Write during
communication)
setting
running
0
Enabled
0.01/0.01* See J-28
Enabled
0.01/0.01* See J-28
Enabled
0.01/0.01
80
Disabled
0.01/0.01
80
Enabled
0.01/0.01
0.0
Enabled
0.01/0.01
60
Enabled
0
Disabled
0.1/0.01
See J-28
Enabled
stall
0
Disabled
stall
stall
stall
0.01/0.01
0.0
Enabled
0.01/0.01
0.0
Enabled
0.01/0.01
0.0
Enabled
0.01/0.01
0.0
Enabled
0.01/0.01
0.0
Enabled
0.01/0.01
0.0
Enabled
0.01/0.01
0.0
Enabled
:valid,
:invalid)
Vector control
V/f
Reference
Speed
Torque
Position
Constant
section
control
control
control
●/●
●/●
−/●
●/●
●/●
●/●
●/●
−/●
●/●
●/●
●/●
●/●
−/●
−/−
−/−
−/−
−/−
−/−
−/−
●/−
−/−
−/−
●/−
−/−
−/−
●/−
−/−
−/−
●/−
−/−
−/−
−/−
−/−
−/−
●/−
●/−
−/−
−/●
−/●
−/−
−/●
−/−
−/●
●/●
●/●
−/●
●/●
●/●
●/●
●/●
●/●
●/●
●/●
●/●
●/●
−/●
●/●
●/●
−/●
5.6
5.1.2
5.1.2
5.7
5.8
5.8
5.9
5.10
5.12
5.13
5.14
4.1.2
4.1.3

Hide quick links: