4.1.2 DIP Switch 1 (SW1)

This DIP switch configures the DVI input sources and the DDC signals.
Switch
Name
1
PWRDVI1
2
PWRDVI2
3
OUT-LEVEL
4
N.C.
5
A0_0
6
A1_0
7
A0_1
8
A1_1
4.1.2.1
PWRDVI1/ PWRDVI2
The first two switches are used to enable/ disable the two DVI Input Ports:
PWRDVI1
Function
on
DVI Input Port 0 is activated
off
DVI Input Port 0 is deactivated
PWRDVI2
Function
on
DVI Input Port 1 is activated
off
DVI Input Port 1 is deactivated
4.1.2.2
OUT-LEVEL
The next switch 3 is used to set the back termination for the output level. The use of back terminations is
highly recommended for best signal integrity.
Factory Settings
This switch is set to off by factory and should only be changed after consultation with
the Beckhoff Support.
Note
CU8810-0010
Function
Activate DVI Input Port 0 (X40)
Activate DVI Input Port 1 (X41)
Set output level for DVI Output
Not used
Address switch A0 for DVI Input Port 0 (X40)
Address switch A1 for DVI Input Port 0 (X40)
Address switch A0 for DVI Input Port 1 (X41)
Address switch A1 for DVI Input Port 1 (X41)