Table of Contents

Advertisement

Lestronic II Charger

NOTICE
This charger is available for 115 VAC or 230 VAC operation (nominal). Confirm the
charger installed is correct for the AC voltage power source before connecting the charger.
Connecting to improper voltage will damage the charger.
NOTICE
Sealed Lead Acid batteries (SLA) must be charged with a charger configured for SLA
batteries. Use of any other charger will result in damage and premature failure of the
batteries.
Description of Operation
The Lestronic II charger is a semi-automatic charging system. The charger will turn itself ON
when the AC power cord is connected to the AC power source and turn itself OFF when the
batteries are fully charged.
Charging with the Lestronic II Charger
Note: Opportunity charging is not recommended. For maximum battery life, it is recommended
that the batteries be discharged a minimum of 50% before starting a charging cycle.
This charger requires a standard household electrical circuit rated at minimum of 15 Amps.
Consult an authorized electrician if you do not know the configuration of your circuits.
1. Park the vehicle at an authorized charging station. Refer to Parking in the Driving section.
2. Connect the charging cord to the AC power receptacle.
3. The charger should start automatically.
When plugged in, the charger assumes that the batteries require charging and will charge for
a minimum of approximately 4-hours. This charger should not be plugged in until the batteries
are discharged beyond 50% or the batteries may be overcharged.
Page 48
B-210 / B-200 Curtis DC System Operator Manual
MB-210-14

Advertisement

Table of Contents
loading

This manual is also suitable for:

B-200B0-210-36B0-210-36ambB0-200-36

Table of Contents