3.7

Connecting Power

This product is intended to be supplied with a Listed DC Power Source, rated 9-
36Vdc (For UNO-1372GH is 10~36 Vdc), 4A minimum and Tma 60 degree C. If fur-
ther assistance is required, please contact Advantech customer support for additional
information.
3.8

Installing lockable kit (For UNO-1372GH Only)

3.8.1

Purpose

The mainly usage of lockable kit is for fixing external I/O cable with UNO System
from any abnormally pulling of cable or accidently vibration of system. In hazardous
location, any sparks will cause exposure and damage the system, with lockable kit, it
can make sure all cables been secured tightly on system to prevent unintentionally
dropping cables.
3.8.2

Part number

UNO-2000-LKAE (with 10 sets inside, only UNO-1372GH-E3AE have 2 sets as
default package).
3.8.3

Lockable kit configuration

UNO-1372G User Manual
Lockable screw:
To screw into the hole behind I/O on UNO system.
Lockable Stopper:
Cables need to pass through the lock stopper then
screw tightly to fit cable's dimension.
Lockable Nut:
For Fixing the lock stopper.