General Specifications; Meter Specifications For A Mid Certified Evse (Europe); Ambient Conditions - ABB Terra AC User Manual

Hide thumbs Also See for Terra AC:
Table of Contents

Advertisement

Technical data
7.2

General specifications

Parameter
Compliance and safety
Certification
IP or NEMA rating
IK rating according to IEC 62262 (en-
closure and display)
EMC rating
7.3

Meter specifications for a MID certified EVSE (Europe)

Parameter in 2014/32/EU directive
Mechanical environment
Electromagnetic environment
7.4

Ambient conditions

Parameter
Operation temperature
Operation temperature for MID certified
models
Storage temperature
42
A5 = not applicable for socket version
A6 = authorization = RFID enabled
A7 = Ethernet = single
A8 = metering = not certified
A9 = SIM slot = applicable
A10 = display = not applicable
The '0' is an empty field.
Specification
IEC/EN 61851-1
IEC/EN 62311
IEC/UL 62479
IEC/UL 62955 TüV listed conforming to
UL 2594, UL 2231-1, UL 2231-2, UL 1998
CSA C22.2. NO.280
CE, MID, TüV, Energy Star
The type plate shows the specification. Re-
fer to section 2.3.
IK10
IK8+ for an operation temperature be-
tween -35 and -30 °C
IEC 61851-21-2, EN 61000-6-1, EN 61000-6-2,
EN 61000-6-3, EN 61000-6-4, EN 61000-3-2,
EN 61000-3-3, EN 61000-3-11, EN
61000-3-12 CE RED- WLAN / RFID / E-UTRA:
EN 300 328 V2.1.1, EN 300 330 V2.1.1, EN 301
908-1 V11.1.2, EN 301 908-13 EN 50470-1, EN
50470-3 FCC Part 15 Class B
Specification
M1
Shock and vibrations of low significance
E2
Value
-35°C to +50°C
-30°C to +55C
-40°C to +80°C
BCM.V3Y00.0-EN | 002 - DRAFT

Advertisement

Table of Contents
loading

Table of Contents