Lpg Tank, Fill - Yale VERACITOR GCC030VX Operating Manual

Table of Contents

Advertisement

A.
SWING OUT BRACKET
1.
LPG TANK
2.
TANK STRAP
3.
QUICK DISCONNECT FITTING
4.
HYDROSTATIC RELIEF VALVE
5.
MANIFOLD BLOCK
6.
ALIGNMENT PIN

LPG Tank, Fill

WARNING
Read and follow all the refueling precautions and
instructions under Liquefied Petroleum Gas (LPG).
Removable LPG tanks must be removed from the fork
lift before filling.
NOTE: The following instructions are general procedures.
There is a variation in equipment for filling LPG tanks. The
local authorities that have jurisdiction have specific rules
and regulations for filling LPG tanks. Make sure these rules
and regulations are available and understood.
1. Check the gauge on tank to make sure it needs filling.
During the fill operation, the LPG tank must be in a position
so that the liquid level indicator will always be in the vapor
space above the liquid level.
Legend for Figure 43
B.
7.
STOP PIN
8.
BRACKET HANDLE
9.
BRACKET PIVOT
10.
GAS SPRING ()
11.
BRACKET RELEASE PIN
2. Open the liquid outlet valve and bypass return valve on
the storage tank.
3. Start the pump.
4. Connect the supply hose to the quick disconnect fitting
on the LPG tank (see Figure 43). If the LPG tank has an
auxiliary fill fitting, connect the supply hose to this fitting.
Make sure the correct adapter is used to connect the sup-
ply hose to the auxiliary fill fitting.
5. Open the vent valve on the liquid level indicator.
6. Open the fuel valve on the LPG tank.
7. Open the valve on the end of the supply hose.
8. Watch for a discharge from the vent valve on the liquid
level indicator. When a cloud of visible vapor appears, the
LPG tank is full. Do not fill the LPG tank to more than the
Maintenance
171

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents