Teledyne Linea CL LA-CM-08K08A User Manual page 16

2k, 4k, 8k and 16k monochrome cmos line scan
Table of Contents

Advertisement

The following figure of the Linea CL back end shows connector and LED locations. See the
Mechanical Specifications section for details on the connectors and camera mounting dimensions.
Power Connector
WARNING! Grounding Instructions
It is extremely important that you apply the appropriate voltages to your camera.
Incorrect voltages may damage the camera. Input voltage requirements: +5 VDC to
+24 VDC (2k and 4k models), 1 Amp. +12 VDC to +24 VDC (8k and 16k models), 2
Amp. Before connecting power to the camera, test all power supplies.
Hirose 6-pin Circular Male (Mating Part: HIROSE HR10A-7P-6S)
Pin
Description
1
+5 V to +24 V DC (2k and 4k)
+12 V to +24 V DC (8k and 16k)
2
+5 V to +24 V DC (2k and 4k)
+12 V to +24 V DC (8k and 16k)
3
+5 V to +24 V DC (2k and 4k)
+12 V to +24 V DC (8k and 16k)
14  Linea CL Camera Setup
Power
Control & Data
Status
Pin
Description
4
GND
5
GND
6
GND
Hirose 6-pin
+5V to +24V DC
(2k and 4k)
+12V to +24V DC
(8k and 16k)
Camera Link 26-pin
SDR26 connectors
Diagnostic LED
Linea CL Series Camera