Sinclair SDV 6 SWC-61 User & Installation Manual page 44

Advertisement

Parameter
Parameter Name
Code
T1 temperature
N13
difference when
auxiliary heater is on
N14
T1 temperature
difference when
auxiliary heater is off
N15
Auxiliary heater used
alone
N16
Auxiliary heater
on/off
N17
IDU cold draft
prevention
temperature settings
N18
Fan speed setting in
cooling standby
mode
N19
Standby fan speed
L1 range in dry
mode
Default
Parameter Range
Value
0-7
4
0-10
6
00/01
00
00/01/02
00
00/01/02/03/04
00
00/01/02/03/04/05/06/
01
07/14
00/01/02/03
01
41
Remarks
0-7 indicates 0 - 7°C
(Accuracy is 1°C)
0-10 indicates -4 - 6°C
(Accuracy is 1°C)
00: No
01: Yes
00: Auto
01: Forced on
02: Forced off
Common IDU:
00: 15, 01: 20, 02: 24, 03: 26, 04: anti-cold wind
invalid
FAPU: 00: 14, 01: 12, 02: 16, 03: 18, 04: anti-cold
wind invalid
Fan coil unit: 00: 32°C, 01: 34°C, 02: 36°C, 03:
38°C, 04: anti-cold wind invalid, water inlet
temperature.
00: Speed 1
01: Speed 1
02: Speed 2
03: Speed 3
04: Speed 4
05: Speed 5
06: Speed 6
07: Speed 7
14: Fan speed before going to standby mode
00: Fan off
01: L1
02: L2
03: Speed 1