  • Page 4: Installation Method

    1. Installation Method 1. First, select an installation location, leave a slot according to dimension of power switch. The slot is for assembly power switch. 2. Connect the power cords of weekly timer and power switch by following the figure shown below, and make the power cord of power switch and twisted-wire with crystal joint through electric box <3>.
  • Page 5 Note:For prevent disturbance power cord and Power cord of power switch signal wire should be wired (Brown one is live wire, in different wire grooves. blue one is neutral wire.) Twisted-wire with crystal joint (Connect with telephone wire base) Power cord of weekly timer Fig.2 Installation sketch Names...
  • Page 6: Notice

    2. Notice 1.Ensure the specification of power for weekly timer, or the weekly timer may work abnormally, or even damage the weekly timer. 2. Ensure the correct joint of communication wire, or there will be communication error. 3. Don’t place the weekly timer to where there is water leakage or direct sunshine.
  • Page 7: Structure Diagram

    4. Structure Diagram Fig.3 Joint sketch Structure of weekly timer is as shown in fig.4: Fig.4.
  • Page 8 Instruction Instruction Displays unit’s no. Displays off control Displays group control Display present time in week Displays single control Displays present time in Hr:Min Displays timer time in Confirm week. Displays timer Increment Displays timer state Decrement Displays timer period Cancel/delete Displays timer on time Single c...
  • Page 9 Display of default page (fig.5): Fig.5. 1) If the unit is under controlled state, the no. of corresponding unit would be displayed. 2) If the unit is in on state, the no. of corresponding unit would contains an underline; if the unit is in off state, the no. of unit will not have underline.
  • Page 10 Note: 1) Differences between “long-press” and “short-press” mentioned below: press time for long-press is not shorter than 5s, and the time for short-press is shorter than 5s. 2) Corresponding unit no. of the selected unit contains an underline, and the corresponding unit no. of the not selected unit contains no underline.
  • Page 11: Operation Guidance

    5. Operation Guidance 5.1 Single/group control setting Single control setting (fig.6) Fig.6. 1) Under default page, short-press “single/group” to enter single control setting. “SINGLE” displayed and all unit numbers be displayed. 2) Press “dec” or “inc” to select the unit that need to be set. 3) Short-press “single/group”...
  • Page 12 2. Group control setting (fig.7) Fig.7. 1) Under default page, long-press “single/delete” to enter group control setting. “Group” is displayed and numbers for all unit be displayed. 2) Press “dec” or “inc” and selected the unit that needs setting. 3) Short-press “single/delete” and select unit, when short-press “single/delete”...
  • Page 13: On/Off Setting

    5.2 On/Off Setting (fig.8) Note: This setting can only be conducted when single/group setting is well set. 2. On/off setting can be conducted with timer setting. Fig. 8. Press “On/Off” to turn on the unit; repress “On/Off” to turn off. Under single control, only one unit can be turned on/off, under group control, then the several selected units can be turned on/off.
  • Page 14: Timer Setting

    5.3 Timer Setting Note: 1. Timer setting can only be conducted when single/group control has been set well. 2. Timer setting can go with on/off setting. 3. Weekly timer needs time to save and process data, no button can work during that period. Fig.9.
  • Page 15 Fig.10. 2) When canceling timer setting to the selected unit, long-press “cancel/delete” after process 1), “TIMING” and “OFF” blinks, then timer is in invalidate state. At this time long-press “cancel/delete” can switch timer between validate and invalidate state. Only under timer validate state can set timer. Short-press “cancel/delete”...
  • Page 16 Fig.11. 3) When timer is validate, short-press “timer/time” to enter timer week setting. Press “dec” or “inc” can select a certain day in one week. Short-press “cancel/delete” back to process 2) (fig.11).
  • Page 17 Fig.12. 4) Short-press “timer/time” again to begin setting timer period of timer. Press “dec” or “inc” can select a certain time period in a certain day in a week. Short-press “cancel/delete” back to process 3) (fig.12). 5) Short-press “timer/time” again to begin setting timer on and timer off.
  • Page 18 Fig.13 6) To cancel timer at a certain day, long-press “cancel/delete” in process 3) and “TIMING OFF” displayed. It is available to select other days to conduct timer setting (fig.13). E.g.: In fig.13, timer setting at Monday for unit 1 and unit 9 is eleted.
  • Page 19 Fig.14. 7) To cancel timer of a certain time period in a certain day, long-press “cancel/delete” in process 4) and “TIMING OFF” displayed. But timer setting can be conducted at other time period at that day (fig.14). E.g.: In fig.14, timer setting for the 3 time period in Thursday or unit 1 and unit 9 are deleted.
  • Page 20: Consult On/Off And Timer

    5.4 Check Unit On/Off and Timer (fig.15) Fig.15. 1) Under default page, number of the controlled unit is displayed. If there is an underline under the unit, means the unit is under on state, otherwise it is in off state. shoot-press “timer/time” to begin consulting unit timer time, and numbers for all units will be displayed.
  • Page 21: Time Setting

    5.5 Time Setting (fig.16) Fig.16. 1) Long-press “timer/time” under default page can begin time setting, and the minute part for time part blinks. 2) Press “dec” or “inc” to select the minute part of set time. Short-press “timer/time” then hour part blinks. Press “dec” or “inc”...
  • Page 22: Key-Lock Setting

    5.6 Key-lock Setting (fig.17) Fig.17. 1) Long press " cancel/delete " button to enter wire controller key-lock operation. 2) "CC" will be displayed when the central controller is enter the key-lock function status. All the unit number will be displayed and the smallest unit number will be blinked.