Summary of Contents for Sinclair SWC-86A

  • Page 1 USER AND INSTALLATION MANUAL SWC-86A AIR CONDITIONING...
  • Page 2 This manual gives detailed description of the precautions that should be brought to your attention during operation. In order to ensure correct service of the wired controller please read this manual carefully before using the unit. For convenience of future reference, keep this manual after reading it.
  • Page 3: Table Of Contents

    CONTENTS Quick Operation Process Features Main Parameters Overview Basic Setting Fan Speed Setting Timer Setting Child Lock Setting Indoor Temperature Display Project Commissioning Installation...
  • Page 4: Quick Operation Process

    1 Quick Operation Process On/Off switch Mode Adjust temperature Fan speed 1.1 Auxiliary function operation Timer function: Press to confirm timing Adjust time Timing Press and hold for 3s to cancel the timing ECO function: Press and hold for 2s Enable the ECO mode 2 Features Modbus...
  • Page 5: Main Parameters

    3 Main Parameters Networked: SWC-86A Model Rated voltage 220-240V~, 50/60Hz Substantially resistive load: max. 1A /output, total: max. 1A Rated Current Inductive load: max. 0.9A /output, total: max. 1A, PF=0.93 Temperature limit -15°C to 43°C Humidity ≤RH90 % Degree of pollution Action Type 1B.U...
  • Page 6: Overview

    4 Overview Fan speed display Operating indicator Operating mode display Timer display display Mode Fan speed Adjustment Timing On/Off /ECO button...
  • Page 7: Basic Setting

    5 Basic Setting Press . The operating status LED turns on and the air 1 On/Off conditioner starts operating; Press again. The operating status LED turns off and the air conditioner stops operating. The icon is displayed when the air conditioner is off. 2 Mode Press to change the operating mode according to the order...
  • Page 8: Fan Speed Setting

    3 Temperature Except in the Fan mode, press to adjust the set setting temperature indoors. Press and hold the button to increase or decrease the set temperature continuously. 4 ECO setting Press and hold bottom for 2s to enable ECO mode. Cooling ECO: 26℃, low fan speed;...
  • Page 9: Timer Setting

    7 Timer Setting 1 Timed On setting: Press or switch off the screen to confirm the timing Press and hold to cancel Press and hold to cancel 2 Timed Off setting: Press or switch off the screen to confirm the timing Press and hold to cancel Press and hold...
  • Page 10: Child Lock Setting

    8 Child Lock Setting 1 Enable child lock: The wired controller doesn't respond when buttons are pressed and flashes. Press and hold the two Enable child lock buttons for 1.5s 2 Disable child lock Press and hold the two Disable child lock buttons for 1.5s 9 Indoor Temperature Display ●...
  • Page 11: Project Commissioning

    10 Project Commissioning 10.1 Restore Factory Default Settings ● Touch and hold at the same time for 5s, and the wired controller will restart with its parameters restored to the factory settings. 10.2 Error Display ● When the sensor fails, the LCD displays the error code E1 in the Temperature Setting display area;...
  • Page 12 Parameter Parameter Default Parameter Range Remarks Code Name Value Wired controller 01-32 address 00:Two-pipe cooling and heating 01:Two-pipe cooling 02:Two-pipe cooling +Auxiliary electric heater Two-pipe/four-pipe 03:Two-pipe heating selection +Auxiliary electric heater 04:Two-pipe cooling and heating +Auxiliary electric heater 05:Four-pipe ECO cooling temperature 17°C to 30°C / 62°F to 86°F 26°...
  • Page 13 Parameter Parameter Default Parameter Range Remarks Code Name Value 00: 0 second 05: 5 seconds 10: 10 seconds Duration of preventing 15: 15 seconds cold wind 30: 30 seconds 60: 60 seconds 90: 90 seconds Version Read only 10.4 Modbus Transmission rate: 9600 bps;...
  • Page 14 Default Register Command Parameter Name Parameter Range Value Address Fan always on 03/06/16 /always off (After 00: OFF; 01: ON setting temperature) 00:°C degrees Celsius Select temperature 03/06/16 01:°F degrees Fahrenheit unit Cooling/Fan 03/06/16 temperature 0C° / 0°F -10C°~10°C/ -18°F~18°F compensation Heating/Auxiliary electric heater...
  • Page 15 Default Register Command Parameter Name Parameter Range Address Value 00: Two-pipe cooling and heating 01: Two-pipe cooling 02: Two-pipe cooling +Electric auxiliary heating 03/06/16 System type 03: Two-pipe heating +Electric auxiliary heating 04: Two-pipe cooling and heating +Electric auxiliary heating 05: Four-pipe Restore factory 0: General;...
  • Page 16: Installation

    CAUTION ● The default status of Valve1 and Valve 2 will depending on the system state. 11 Installation 11.1 Installation Precautions ● To ensure correct installation, read the "Installation" section of this manual. ● The content provided here covers warnings, which contains important information about safety that must be followed.
  • Page 17 11.2 Installation Accessories Please check that you have all the following parts. Name Remarks Wired controller Used to install the wired controller on the Philips head screw, M4×25 electrical box Installation & Owner’s Manual Used to install the wired controller on the Plastic support bar electrical box Prepare the following parts in the field:...
  • Page 18 11.3 Product Dimensions (mm) Mounting hole: 60 11.4 Installation Method 1. Remove rear cover of the wired controller: insert a slotted-head screwdriver into the bottom buckle of the wired controller, and rotate in the direction indicated to remove the rear cover. Remove the flat cable connecting the front and rear PCBs and remove the front cover of the wired controller.
  • Page 19 2. Install support bars: Adjust the lengths of the two plastic support bars in the accessories. Ensure that the rear cover of the wired controller stays level with the wall when installed on the screw post of installation box (cassette type). Use a cutting tool to adjust the lengths of the two plastic support bars Screw post of the installation...
  • Page 20 PROHIBIT ● This product must be installed by a specialized technician. Do not connect cables when the unit is active. ● Do not connect the neatral and live wires to the X/Y/E ends. Otherwise, the wired controller will be burnt. WARNING ●...
  • Page 21 Two-pipe heating + Auxiliary electric heater Two-pipe cooling/cooling and Two-pipe cooling + Auxiliary electric heater heating (Networked) Two-pipe cooling and heating + Auxiliary electric heater (Networked) L Hf Mf Lf V2 N L Hf Mf Lf V1 V2 N Valve Valve Valve Normally...
  • Page 22 4. Insert the cable of the rear cover into the installation box (cassette type). Use pan head screws to fix the rear cover of the wired controller on the installation box (cassette type); connect the flat cable that connects the front and rear PCBs. Installation box (cassette type) Cross recessed head screw...
  • Page 23 5. Buckle the front cover of the wired controller on the rear cover as shown in the following figure. Then buckle the lower ends of the front and First buckle the upper ends of the front rear covers of the wired controller. and rear covers of the wired controller.