Parameter
Parameter Name
Code
N02
IDU up/down swing
setting
N03
IDU left/right swing
setting
N04
Whether the display
board of IDU
receives remote
control signals
N05
Buzzer of the IDU
rings
N06
Light (display panel)
setting
N07
Temperature unit
N08
Mode changeover
time interval in the
auto mode (min)
N11
Set outdoor
temperature value
when auxiliary
heater is on
N12
Indoor temperature
when auxiliary
heater is on
Default
Parameter Range
Value
00/01/02/03/04
01
00/01
01
00/01
00
00/01/02
02
00/01
01
00/01
00
00/01/02/03
00
-25°C to 0°C
0°C
10°C to 30°C
24°C
40
Remarks
00: None
01: Available
02/03: Reserved
04: Q4/Qmin four air vents
Note: The IDU can automatically identify up/down
swing, so this function is invalid
00: None
01: Available
Note: The IDU can automatically identify up/down
swing, so this function is invalid
00: Yes
01: No
00: No
01: Yes
02: remote controller only
00: Off
01: On
00: Celsius
01: Fahrenheit
00: 15min
01: 30min
02: 60min
03: 90min
Note: Accuracy is 1°C.
(Accuracy is 1°C)

Advertisement