Section6

Timing Charts

Timing Charts
The following shows the timing charts when communication is performed with external
devices.
The parts in which specific values are stated in the timing chart are the times that do not
depend on the sampling cycle.
 Basic Operation
Laser beam emission
Internal processing
Judgment output
Linear output
T1
Time during which the mea-
sured value is determined
from the laser beam emis-
sion
T8
Update cycle of judgment
output
T11 Response time of linear
output
ZS-HL
6-18
User's Manual
a
OFF
ON
Item
Minimum
Sampling cycle
b
a
T1
Average
Maximum
Sampling
cycle × 3
500 µs
T8
b
T11
Remarks
When the measure-
ment is performed con-
tinuously and the
amount of light is stable
It changes depending
on the way the mea-
sured value fluctuates.