Setting the Filter Function
Setting the Filter Function
Set the conditions for filtering information obtained from the sensor.
Waveform
when filter
function is
not set
SMOOTH
Average
value
Differentiation
Setting SMOOTH
The intermediate value of multiple sets of data can be output as the measurement result.
This function removes any abnormal values such as spiking that occur when the shape of
the workpiece suddenly changes during measurement.
Example: To remove spiking
FUN Mode-[FILTER]-[SMOOTH]
Setting
OFF
ON
When "HI-SPEED" is set in the measurement mode, [OFF] is set.
ZS-HL
5-12
User's Manual
Displacement
Smooth
Displacement
0
Abnormal values such as spiking that occur when the shape
of the workpiece suddenly changes during measurement.
The smoothing function can remove spikes
The smooth function is not used.
The intermediate value of the past 15 measured values is set as the measurement
result at each sampling cycle. (default value)
Spike-like changes are
removed.
Changes are smoothed out.
Changes are extracted to
eliminate displacement value.
Time
Time