Settings For Terminal Block Output; Real-Time Parallel Output Unit - Omron ZS-HL Series User Manual

Smart sensor
Hide thumbs Also See for ZS-HL Series:
Table of Contents

Advertisement

Settings for Terminal Block Output

The following describes the methods for connecting a real-time parallel output unit (ZG-
RPD_1) and outputting the measured value or judgment result at high speed. The
measured value is converted to 16-bit binary data in the maximum steps of 65536, and is
output.
In Multi-Task mode, you can output all of the judgment results of multiple tasks together.

Real-Time Parallel Output Unit

 Connection of a Real-Time Parallel Output Unit
Hang the hook that is on the rear side of the real-time parallel output unit to the DIN
track and attach it there. Then, connect the connector of the Sensor Controller to the
RS-232C connector of ZS-HLDC_1, and use the Sensor Controller.
18-pole
terminal block
(detachable)
 Alignment of the Terminal Block
[Type of Connectors Used]
• ZG-RPD body side Þ SL 3.5/18/90F-ORG (made by Weidmuller)
• Cable connection side Þ BL 3.5/18F-ORG (made by Weidmuller)
Connect to the RS-232C
connector of
the ZS-HLDC.
Connector
ZG-RPD
ERR indicator
(lit color: red)
ZG-RPD
PARALLEL OUTPUT UNIT
RS-232C
DATA 0
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15
Pin Nos.1 to 16
Parallel output
Signal names: D0 to D15
Settings for Terminal Block Output
ZS-HLDC
DIN track
PWR indicator
(lit color: green)
MADE IN JAPAN
ERR
PWR
GATE
Pin No.17
Gate signal
Signal name: GATE
Section6
Pin No.18
not used
ZS-HL
User's Manual
6-9