13 | Online Measurement and Calibration
13.3 Online calibration of multipoint adjustment
80 / 136
channels
Example: measurement of wheel force
– Physical property 'wheel force' not directly measureable
– Load transfer through suspension kinematics
– Physical value at sensor position defined by vehicle
– Curve definition by online adjustment at vehicle
Force at sensor
Force at wheel
1.
Create a multipoint adjustment measurement channel. To create a multipoint channel,
see chapter 'Configuring a multipoint adjustment [} 61]'.
2.
Download the configuration on the VCU MS 50.4P. To connect the VCU MS 50.4P to
RaceCon, see chapter 'Setting up a new RaceCon Project'.
3.
Click on the desired channel in the VCU MS 50.4P Project Tree.
4.
Double-click on a measurement channel in the Data Area to open the online view.
Click to open
measurement
channels in data
view
Double-click
to open
online view
5.
Click on 'Calibrate adjustment points' to open calibration window.
6.
Apply the desired physical condition to the sensor (e.g. by applying a force on the
wheel).
7.
Enter the physical value in the value column of the desired calibration point
(e.g. 745 N).
Vehicle_Control_Unit_VCU_MS_50.4P_Manual