16 | Lap Trigger
16.3.1 Time based retrigger protection
16.3.2 Distance based retrigger protection
110 / 136
Channel
Laptrigger_laptime_dls
Laptrigger_laptime_best_dls
Laptrigger_laptimeold_dls
Laptrigger_laptimeseg_dls
Laptrigger_lapctr_dls
Trigger is locked for 5 s after main trigger was received.
To deactivate time based retrigger protection, set 'Retrigger lock time' to 0 ms.
Define settings for lap timing
(main trigger).
Define settings for sub trigger.
Not applicable with a GPS lap trigger.
5000ms
Main Trigger
Trigger is locked until configured min distance (i.e. 80 % → 3200 m) of track distance (i.e.
4000 m) has been covered. To deactivate distance based retrigger protection, set min dis-
tance to 0 %.
Change signal for vehicle speed,
if desired.
Enter minimum speed for
trigger release.
Define settings for distance
based retrigger protection.
Define settings for distance
based forced trigger.
Vehicle_Control_Unit_VCU_MS_50.4P_Manual
Function
Running laptime
Laptime of best lap
Laptime of last lap completed
Segment time of last segment
Number of completed laps