13.2.2 Performing the online offset calibration
Bosch Motorsport
In the channel view
VCU MS 50.4P has to be connected to RaceCon to calibrate the sensor's offset.
1.
Apply the desired physical condition to the sensor (e.g. 1 G to an acceleration sensor).
2.
Open the measurement channel's online page by double-clicking on the measure-
ment channel name in the Data Area.
3.
Enter the physical target value (e.g. 1 G) and press the 'Calibrate' button.
Calibration
target value
Initiate
calibration
The sensor's offset is now calibrated.
Vehicle_Control_Unit_VCU_MS_50.4P_Manual
Online Measurement and Calibration | 13
Check box to enable online
offset calibration and enter
desired physical target value
Activate switch
to enable online
calibration