13.3 Online calibration of multipoint adjustment
Bosch Motorsport
channels
Example: measurement of wheel force
– Physical property 'wheel force' not directly measureable
– Load transfer through suspension kinematics
– Physical value at sensor position defined by vehicle
– Curve definition by online adjustment at vehicle
Force at sensor
Force at wheel
1.
Create a multipoint adjustment measurement channel. To create a multipoint channel,
see chapter 'Configuring a multipoint adjustment [} 57]'.
2.
Download the configuration on the Vehicle Control Unit VCU. To connect the Vehicle
Control Unit VCU to RaceCon, see chapter 'Setting up a new RaceCon Project'.
3.
Click on the desired channel in the Vehicle Control Unit VCU Project Tree.
4.
Double-click on a measurement channel in the Data Area to open the online view.
Click to open
measurement
channels in data
view
Double-click
to open
online view
5.
Click on 'Calibrate adjustment points' to open calibration window.
6.
Apply the desired physical condition to the sensor (e.g. by applying a force on the
wheel).
7.
Enter the physical value in the value column of the desired calibration point
(e.g. 745 N).
Vehicle_Control_Unit_VCU_Manual
Online Measurement and Calibration | 13
Click to open
calibration
window
Analog and physical
value
77 / 136