20.2 Fuel consumption diagnosis/counter reset

Bosch Motorsport
– using fuel consumed (summed-up fuel consumption)
– using fuel flow rate (momentary fuel consumption)
d) Choose input channel and enter adaption factor. Use adaption factor to adapt value of
input channel to:
– 1ml per inc for summed-up fuel consumption
– 1ml/s per inc for momentary consumption
e) Enter factor to correct calculated consumption in device vs. 'real' consumption of
vehicle, if required.
f) Choose method to calculate remaining laps with fuel in tank, if desired:
– using fuel consumption of last lap completed
– using target lap consumption (entered in the field 'Target lap consumption')
g) Choose values to initiate a reset of fuel consumption, if desired:
– Manually using RaceCon
– On 'power down' (assuming that the tank is filled each time the ignition is turned off)
– By signal source as input channel (e.g. a switch connected to input pin)
Press 'Finish' when done.
To display a fuel consumption diagnosis and to reset counters, use the diagnosis page in
RaceCon.
Double-click on any 'fuel_xxx' channel in channel list.
A diagnosis window opens in Main Area.
Settings
overview
Vehicle_Control_Unit_VCU_MS_50.4P_Manual
Fuel Consumption Calculation | 20
Button to reset total
fuel consumption
(Reset with RaceCon
only)
Button to reset fuel
consumption manually
(Can also be triggered )
129 / 136