42
HP ProLiant ML310 Generation 3 Server User Guide
Installing hot-plug SCSI hard drives
When adding SCSI hard drives to the server, observe the following general
guidelines:
•
Hot-plug hard drives must be Ultra320 SCSI drives for optimum
performance. Mixing these types with other drive standards degrades the
overall performance of the drive subsystem.
•
Drives must be the same capacity to provide the greatest storage space
efficiency when drives are grouped together into the same drive array.
1. Remove the bezel ("Unlocking the bezel" on page 22).
2. Remove the hard drive blank.
CAUTION: To prevent improper cooling and thermal damage, do
not operate the server unless all bays are populated with either a
component or a blank.
Need help?
Do you have a question about the ProLiant ML310 Generation 3 and is the answer not in the manual?
Questions and answers