18
HP ProLiant ML310 Generation 3 Server User Guide
Activity
Online
LED (1)
LED (2)
Flashing
Flashing
Off
Off
Off
Off
Hot-plug SATA or SAS IDs
Fault LED
Interpretation
(3)
Flashing
Do not remove the drive. Removing a drive may cause data
loss in non-fault-tolerant configurations.
Either (1) the drive is part of an array being selected by an array
configuration utility; (2) Drive Identification has been selected in
HP SIM; or (3) drive firmware is being updated.
On
The drive has been placed offline due to hard disk drive failure of
subsystem communication failure.
You may need replace the drive.
Off
Either (1) the drive is not configured as part of an array; (2) the
drive is configured as part of an array, but it is a replacement drive
that is not being accessed or being rebuilt yet; or (3) the drive is
configured as an online spare.
If the drive is connected to an array controller, you may replace the
drive online.
Need help?