Technical Data; General Specifications - Leuze electronic MLC 500 Original Operating Instructions

Safety light curtains
Hide thumbs Also See for MLC 500:
Table of Contents

Advertisement

14

Technical data

14.1

General specifications

Tab. 14.1:
Protective field data
Physical resolu-
tion [mm]
14
20
30
40
90
Tab. 14.2:
Safety-relevant technical data
Type in accordance with IEC 61496
SIL in accordance with IEC 61508
SILCL in accordance with IEC 62061
Performance Level (PL) in accordance with ISO 13849-1
Category in accordance with ISO 13849-1
Average probability of a failure to danger per hour (PFH
Mission time (T
Tab. 14.3:
General system data
Connection technology
Supply voltage U
Residual ripple of the supply voltage
Current consumption - transmitter
Current consumption receiver
Common value for ext. fuse in the supply line for
transmitter and receiver
Synchronization
Protection class
Degree of protection
Ambient temperature, operation
Ambient temperature, storage
Relative humidity (non-condensing)
Vibration resistance
Shock resistance
Profile cross section
Dimensions
Leuze electronic
Operating range [m]
min.
0
0
0
0
0
)
M
, transmitter and receiver
v
max.
6
15
10
20
20
)
d
M12, 5-pin (transmitter)
M12, 8-pin (receiver)
+24 V, ± 20 %, compensation necessary at 20 ms
voltage dip, min. 250 mA (+ OSSD load)
± 5 % within the limits of U
50 mA
150 mA (without load)
2 A semi time-lag
Optical between transmitter and receiver
III
IP65
0 ... 55 °C
-25 ... 70 °C
0 ... 95 %
2
50 m/s
acceleration, 10 - 55 Hz in acc. with
IEC 60068-2-6; 0.35 mm amplitude
2
100 m/s
acceleration, 16 ms acc. to IEC 60068-2-6
29 mm x 35.4 mm
see chapter 14.2 "Dimensions, weight, response
time"
MLC 520 Host/Guest
Protective field height [mm]
min.
150
1800
150
1800
300
1800
300
1800
450
1800
Type 4
SIL 3
SILCL 3
PL e
Cat. 4
-9
7.73x10
 1/h
20 years
v
Technical data
54

Hide quick links:

Advertisement

Table of Contents
loading