14

Technical data

Table 14.1:
Switch type
Actuator
Actuation directions
Installation point
Actuation speed
Actuation force (pull-out)
Actuation force (slacken)
Actuation force (pull-out) with forced separa-
tion
Actuating path with forced separation
Mechanical life time in accordance with
IEC 60947-5-1
Actuation frequency according to
IEC 60947-5-1
Service life (T
EN ISO 13849-1
Leuze electronic
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
General
) in accordance with
M
E-Stop control device in accordance with
EN 60947-5-5
rope
ERS200-Mxxx-HLR: on longitudinal axis
ERS200-Mxxx-HAR: to the right
ERS200-Mxxx-HAL: to the left
ERS200-Mxxx-HLR: in rope axis
ERS200-Mxxx-HAR: in rope axis to the
right
ERS200-Mxxx-HAL: in rope axis to the left
min. 1 mm/s, max. 0.5 m/s
ERS200-Mxxx-HLR: 83 N
ERS200-Mxxx-HAR: 235 N
ERS200-Mxxx-HAL: 235 N
ERS200-Mxxx-HLR: 63 N
ERS200-Mxxx-HAR: 147 N
ERS200-Mxxx-HAL: 147 N
ERS200-Mxxx-HLR: 90 N
ERS200-Mxxx-HAR: 250 N
ERS200-Mxxx-HAL: 250 N
ERS200-Mxxx-HLR: 8 mm
ERS200-Mxxx-HAR: 14 mm
ERS200-Mxxx-HAL: 14 mm
1,000,000 switching cycles
max. 1 per 6 seconds
20 years
ERS200
Technical data
41