Leuze electronic MLC 500 Original Operating Instructions page 26

Safety light curtains
Hide thumbs Also See for MLC 500:
Table of Contents

Advertisement

Height a
Height b of the upper edge of the protective field of the electro-sensitive protective
of the
equipment
point of
900
opera-
tion
Additional distance C
[mm]
2000
950
1800
1100
1600
1150
1400
1200
1200
1200
1000
1200
800
1150
600
1050
400
900
200
600
0
0
Depending on the specified values you can work with the above-mentioned table in three ways:
1. Given are:
• Height a of the point of operation
• Distance S of the point of operation from the safety sensor, and additional distance C
To be determined is the required height b of the upper beam of the safety sensor and thereby its protective
field height.
Ä Look for the line with the specification of the point of operation height in the left column.
Ä In this line, look for the column with the next highest specification for additional distance C
ð The required height of the upper beam of the safety sensor is up top in the column head.
2. Given are:
• Height a of the point of operation
• Height b of the upper beam of the safety sensor
To be determined is the required distance S of the safety sensor to the point of operation and thereby addi-
tional distance C
Ä In the column head, look for the column with the next lowest entry for the height of the upper beam of
the safety sensor.
Ä Look for the line with the next highest specification of the point of operation height a in this column.
ð In the intersection point of the line and the column, you will find additional distance C
3. Given are:
• Distance S of the point of operation from the safety sensor, and additional distance C
• Height b of the upper beam of the safety sensor
To be determined is the permitted height a of the point of operation.
Ä In the column head, look for the column with the next lowest entry for the height of the upper beam of
the safety sensor.
Ä Look for the next lowest value for real additional distance C
ð In this line, go to the left column: here you will find the permitted height of the point of operation.
Ä Now calculate safety distance S using the general formula acc. to ISO 13855 (see chapter 6.1.1 "Cal-
culation of safety distance S").
ð The larger of the two values S
Leuze electronic
1000
1100
1200
to the danger zone [mm]
RO
950
850
850
1100
950
950
1150
1100
1000
1200
1100
1000
1200
1100
1000
1150
1050
950
1050
950
800
950
750
550
700
0
0
0
0
0
0
0
0
.
RO
and S
RT
1300
1400
1600
800
750
700
850
800
750
900
850
750
900
850
650
850
800
0
750
700
0
500
450
0
0
0
0
0
0
0
0
0
0
0
0
0
RO
is to be used.
RO
MLC 520 Host/Guest
1800
2000
2200
550
400
0
550
0
0
450
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
RO
RO
RO.
in this column.
Mounting
2400
2600
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
.
RO
.
26

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents