Leuze electronic MLC 500 Original Operating Instructions page 37

Safety light curtains
Hide thumbs Also See for MLC 500:
Table of Contents

Advertisement

Tab. 7.1:
Pin assignment transmitter
Pin
Core color (CB-M12-xx000E-5GF)
1
Brown
2
White
3
Blue
4
Black
5
Gray
FE
The polarity of the supply voltage selects the transmission channel of the transmitter:
• VIN1 = +24 V, VIN2 = 0 V: transmission channel C1
• VIN1 = 0 V, VIN2 = +24 V: transmission channel C2
The wiring of pin 4 determines the transmitting power and thereby the range:
• Pin 4 = +24 V: standard range
• Pin 4 = 0 V or open: reduced range
+ 24V
-A1
1
MLCx00T
3
0V
FE
+ 24V
-A1
3
MLCx00T
1
0V
FE
1
Transmission channel C1, reduced range
2
Transmission channel C1, standard range
3
Transmission channel C2, reduced range
4
Transmission channel C2, standard range
Fig. 7.2:
Connection examples transmitter
Leuze electronic
4
5
2
4
5
2
+ 24V
+ 24V
-A1
1
0V
0V
FE
FE
+ 24V
+ 24V
-A1
3
0V
0V
FE
FE
MLC 520 Host/Guest
Electrical connection
Transmitter
VIN1 - supply voltage
n.c.
VIN2 - supply voltage
RNG - range
FE - functional earth, shield
FE - functional earth, shield
1
4
MLCx00T
3
5
2
3
4
MLCx00T
1
5
2
+ 24V
2
0V
FE
+ 24V
4
0V
FE
37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents