Leuze electronic MLC 500 Original Operating Instructions page 57

Safety light curtains
Hide thumbs Also See for MLC 500:
Table of Contents

Advertisement

B
R
Fig. 14.3:
Dimensions of Guest transmitter and Guest receiver
Effective protective field height H
the circles labeled with R.
Calculation of the effective protective field height
H
[mm]
PFE
H
[mm]
PFN
A
[mm]
B
[mm]
C
[mm]
Tab. 14.8:
Additional dimensions for calculating the effective protective field height
R = resolution
14 mm
20 mm
30 mm
40 mm
90 mm
Tab. 14.9:
Dimensions (nominal protective field height), weight and response time for Host devices
Device type
Type
MLC...-300
MLC...-450
Leuze electronic
H
H
goes beyond the dimensions of the optics area to the outer borders of
PFE
=
Effective protective field height
=
Nominal protective field height (length of the yellow housing part) (see tables below)
=
Total height
=
Additional dimensions for calculation of the effective protective field height (see table below)
=
Value for calculating the effective protective field height (see tables below)
B
6 mm
7 mm
19 mm
25 mm
50 mm
Host transmitter and Host
receiver
Dimensions
Weight
[mm]
[kg]
H
A
PFN
300
366
0.53
450
516
0.68
L = 340
PFE
PFN
A
Host receiver
Response time [ms] acc. to resolution
14 mm
20 mm
8
7
11
9
MLC 520 Host/Guest
Technical data
C
R
C
6 mm
10 mm
9 mm
15 mm
40 mm
30 mm
40 mm
4
4
5
5
90 mm
-
3
57