3rd Power Supply Fail Detect
Enable/Disable
The system can notify you in the event
of a power supply failure. This feature
assumes that three power supply units
are installed in the chassis with one act-
ing as a backup. If you only have one
or two power supply units installed, you
should disable this (the default setting)
with JP13 to prevent false alarms. See
the table on right for pin defi nitions.

5-10 Onboard Indicators

JLAN1/JLAN2 LEDs

The Ethernet ports (located beside the
VGA port) have two LEDs. On each
Gigabit LAN port, the yellow (right)
LED indicates activity while the left
LED may be green, orange or off to
indicate the speed of the connection.
See the table on the right for the func-
tions associated with the left (activity
speed) LED.
Chapter 5: Advanced Serverboard Setup
3rd Power Supply Fail
Detect Enable/Disable
Jumper Settings (JP10)
Jumper Setting
Open*
Closed
JLAN Right LED
(Connection Speed Indicator
LED Color
Off
Green
Amber
5-19
Defi nition
Disabled
Enabled
Defi nition
10 MHz
100 MHz
1 GHz