6-5

Power Supply

6024H-TR
The SuperServer 6024H-TR has a 500 watt redundant power supply consisting of
two power modules. Each power supply module has an auto-switching capability,
which enables it to automatically sense and operate at a 100V - 240V input volt-
age.

Power Supply Failure

If either of the two power supply modules fail, the other module will take the full
load and allow the system to continue operation without interruption. The PWR
Fail LED will illuminate and remain on until the failed unit has been replaced. Re-
placement units can be ordered directly from Supermicro (see contact information
in the Preface). The power supply units have a hot-swap capability, meaning you
can replace the failed unit without powering down the system.

Removing/Replacing the Power Supply

You do not need to shut down the system to replace a power supply unit. The
redundant feature will keep the system up and running while you replace the
failed hot-swap unit. Replace with the same model - SP502-2S (p/n PWS-0049),
which can be ordered directly from Supermicro (see Contact Information in the
Preface).
1. Removing the power supply
First unplug the power cord from the failed power supply unit. Then depress
the locking tab on the power supply unit and pull the unit straight out with the
rounded handle.
2. Installing a new power supply
Replace the failed hot-swap unit with another SP502-2S power supply unit (p/n
PWS-0049). Simply push the new power supply unit into the power bay until you
hear a click. Secure the locking tab on the unit and fi nish by plugging the AC
power cord back into the unit.
Chapter 6: Advanced Chassis Setup