Installing The Chassis Rails - Supero SuperServer 6024H-TR User Manual

Supermicro superserver 6024h-tr servers: user guide
Table of Contents

Advertisement

Chapter 2: Server Installation

Installing the Chassis Rails

Position the fi xed chassis rail sections you just removed along the side of the
6024H-TR/6024H-T making sure the screw holes line up. Note that these two
rails are left/right specifi c. Screw the rail securely to the side of the chassis (see
Figure 2-2). There should be two screws for each side. Repeat this procedure for
the other rail on the other side of the chassis. You will also need to attach the rail
brackets when installng into a telco rack.
Locking Tabs: As mentioned, both chassis rails have a locking tab, which serves
two functions. The fi rst is to lock the server into place when installed and pushed
fully into the rack, which is its normal position. Secondly, these tabs also lock the
server in place when fully extended from the rack. This prevents the server from
coming completely out of the rack when you pull it out for servicing.
Figure 2-2. Installing Chassis Rails
2-5