The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates.
Preface About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 6026TT-HDTRF/ HDIBXRF/HDIBQRF/6026TT-D6RF/D6IBXRF/D6IBQRF. Installation and mainte- nance should be performed by experienced technicians only. The SuperServer 6026TT-HD/D6 series server is a 2U Twin (two serverboards/ nodes in a 2U chassis) rackmount server based on the SC827HD-R1400B server chassis and four Super X8DTT-HF+/X8DTT-HIBXF+/X8DTT-HIBQF+ serverboards.
Page 4
SUPERSERVER 6026TT-HD/D6 Series User's Manual and memory components, this chapter will refer you to the appropriate sections of the manual for their installation. Chapter 3: System Interface Refer to this chapter for details on the system interface, which includes the functions and information provided by the control panel on the chassis as well as other LEDs located throughout the system.
SUPERSERVER 6026TT-HD/D6 Series User's Manual Table of Contents Chapter 1 Introduction Overview ......................1-1 Serverboard Features ..................1-2 Processors ...................... 1-2 Memory ......................1-2 Serial ATA ......................1-2 SAS ......................... 1-2 PCI Expansion Slots ..................1-3 Ethernet Ports ....................1-3 Onboard Controllers/Ports ................
Page 7
Table of Contents Reliable Ground ..................2-3 Removing the Protective Film ................. 2-4 Rack Mounting Instructions ................2-5 Separating the Sections of the Rack Rails ............. 2-5 Installing the Inner Rail Extensions ..............2-6 Outer Rack Rails ..................... 2-7 Checking the Serverboard Setup ..............2-9 Preparing to Power On .................
Page 8
SUPERSERVER 6026TT-HD/D6 Series User's Manual 5-11 Installing Additional Drivers ................5-19 5-12 Confi guring Supero Doctor III ............... 5-20 Chapter 6 Advanced Chassis Setup Static-Sensitive Devices .................. 6-1 Precautions ..................... 6-1 Unpacking ....................... 6-1 Control Panel ....................6-2 System Fans ....................6-2 Fan Confi...
Chapter 1 Introduction Overview The SuperServer 6026TT-HDTRF/HDIBXRF/HDIBQRF/6026TT-D6RF/D6IBXRF/ D6IBQRF is a "2U Twin" server comprised of the SC827HD-R1400B 2U chassis and two X8DTT-HF+/X8DTT-HIBXF+/X8DTT-HIBQF+ serverboards. Please refer to our web site for information on operating systems that have been certifi ed for use with the server (www.supermicro.com).
SUPERSERVER 6026TT-HD/D6 Series User's Manual Note: The SuperServer 6026TT-HD/D6 series system is cableless and does not need or come with SATA/SAS cables. Serverboard Features At the heart of the SuperServer 6026TT are four X8DTT-HF+/X8DTT-HIBXF+/ X8DTT-HIBQF+ dual processor serverboards, which are based on Intel's 5520 (North Bridge) + ICH10R (South Bridge) chipset.
Chapter 1: Introduction PCI Expansion Slots Each X8DTT-HF+/X8DTT-HIBXF+/X8DTT-HIBQF+ has included riser cards that allow it to support two full-sized PCI Express 2.0 x8 expansion cards (in x16 slots), or four total for the server. Ethernet Ports An Intel® network controller is integrated into each of the serverboards to support two Gigabit LAN ports (100/1000Base-T/1000BaseTX, RJ45 output).
Chapter 1: Introduction Server Chassis Features The following is a general outline of the main features of the SC827HD-R1400B 2U chassis. Details on the chassis can be found in Chapter 6. System Power When confi gured as a SuperServer 6026TT-HD/D6 series server, the SC827HD- R1400B includes a redundant (dual) 1400W power supply, which provides power to all four serverboards (nodes).
SUPERSERVER 6026TT-HD/D6 Series User's Manual 2U Twin: System Notes As a 2U Twin confi guration, the 6026TT-HD/D6 series is a unique server system. With two system boards incorporated into a single chassis acting as two separate nodes, there are several points you should keep in mind. Nodes Each of the two serverboards act as a separate node in the system.
Chapter 1: Introduction Contacting Supermicro Headquarters Address: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Web Site: www.supermicro.com Europe Address: Super Micro Computer B.V. Het Sterrenbeeld 28, 5215 ML 's-Hertogenbosch, The Netherlands Tel:...
Page 16
SUPERSERVER 6026TT-HD/D6 Series User's Manual Notes...
Chapter 2: Server Installation Chapter 2 Server Installation Overview This chapter provides a quick setup checklist to get the system up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. This quick setup assumes that your system has come to you with the processors and memory preinstalled.
SUPERSERVER 6026TT-HD/D6 Series User's Manual Choosing a Setup Location • Leave enough clearance in front of the rack to enable you to open the front door completely (~25 inches). • Leave approximately 30 inches of clearance in the back of the rack to allow for suffi...
Chapter 2: Server Installation • Allow the hot plug SATA/SAS drives and power supply modules to cool before touching them. • Always keep the rack's front door and all panels and components on the servers closed when not servicing to maintain proper cooling. •...
SUPERSERVER 6026TT-HD/D6 Series User's Manual Removing the Protective Film Before operating the server for the fi rst time, it is important to remove the protec- tive fi lm covering the top of the chassis, in order to allow for proper ventilation and cooling.
Chapter 2: Server Installation Rack Mounting Instructions This section provides information on installing the SC827 chassis into a rack unit with the quick-release rails provided. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. You should also refer to the installation instructions that came with the rack unit you are using.
SUPERSERVER 6026TT-HD/D6 Series User's Manual Installing the Inner Rail Extensions The SC827 chassis includes a set of inner rails in two sections: inner rails and inner rail extensions. The inner rails are pre-attached to the chassis, and do not interfere with normal use of the chassis if you decide not to use a server rack.
Chapter 2: Server Installation Figure 2-4: Assembling the Outer Rails Outer Rack Rails Outer rails attach to the rack and hold the chassis in place. The outer rails for the SC827 chassis extend between 30 inches and 33 inches. Installing the Outer Rails to the Rack Secure the back end of the outer rail to the rack, using the screws provided.
Page 24
SUPERSERVER 6026TT-HD/D6 Series User's Manual Figure 2-5: Installing Into the Rack Installing the Chassis into a Rack Extend the outer rails as illustrated above. Align the inner rails of the chassis with the outer rails on the rack. Slide the inner rails into the outer rails, keeping the pressure even on both sides.
Chapter 2: Server Installation Checking the Serverboard Setup After you install the system in the rack, you will need to access the inside of the nodes to make sure the serverboard is properly installed. Accessing the Inside of a Node (Figure 2-6) Before removing a node, unplug all the cables that connect to that node.
SUPERSERVER 6026TT-HD/D6 Series User's Manual Preparing to Power On Next, you should check to make sure the SATA drives and the backplane have been properly installed and all connections have been made. Checking the Hard Drives The hard drives are accessable from the front of the server and can be installed and removed from the front of the chassis without removing the top chassis cover.
Page 27
Chapter 2: Server Installation Figure 2-6. Removing a Node from the System 2-11...
Page 28
SUPERSERVER 6026TT-HD/D6 Series User's Manual Notes 2-12...
Chapter 3: System Interface Chapter 3 System Interface Overview There are LEDs on the control panels and on the hard drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specifi...
SUPERSERVER 6026TT-HD/D6 Series User's Manual Control Panel LEDs In addition to the LEDs built into the power and UID buttons, each of the four control panels located on the front of the SC827HD-R1400B chassis has two LEDs that provide you with critical information related their own node. This section explains what each LED indicates when illuminated and any corrective action you may need to take.
Chapter 4: System Safety Chapter 4 System Safety Electrical Safety Precautions Basic electrical safety precautions should be followed to protect yourself from harm and the server from damage: • Be aware of the locations of the power on/off switch on the chassis as well as the room's emergency power-off switch, disconnection switch or electrical outlet.
SUPERSERVER 6026TT-HD/D6 Series User's Manual • This product may be connected to an IT power system. In all cases, make sure that the unit is also reliably connected to Earth (ground). • Serverboard Battery: CAUTION - There is a danger of explosion if the onboard battery is installed upside down, which will reverse its polarites (see Figure 4-1).
Chapter 4: System Safety • Remove any jewelry or metal objects from your body, which are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present. •...
SUPERSERVER 6026TT-HD/D6 Series User's Manual Operating Precautions Care must be taken to assure that the chassis cover is in place when the system is operating to assure proper cooling. Out of warranty damage to the system can occur if this practice is not strictly followed. Figure 4-1.
Chapter 5: Advanced Serverboard Setup Chapter 5 Advanced Serverboard Setup This chapter covers the steps required to install the X8DTT-HF+/X8DTT-HIBXF+/ X8DTT-HIBQF+ serverboard into the SC827HD-R1400B chassis, connect the data and power cables and install add-on cards. All serverboard jumpers and connections are also described.
SUPERSERVER 6026TT-HD/D6 Series User's Manual Unpacking The serverboard is shipped in antistatic packaging to avoid electrostatic discharge. When unpacking the board, make sure the person handling it is static protected. I/O Ports The I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-1 below for the colors and locations of the various I/O ports.
Chapter 5: Advanced Serverboard Setup Processor and Heatsink Installation When handling the processor, avoid placing direct pressure on the label area of the fan. Also, do not place the serverboard on a conductive sur- face, which can damage the BIOS battery and prevent the system from booting up.
Page 38
SUPERSERVER 6026TT-HD/D6 Series User's Manual After removing the plastic cap, use your thumb and the index fi nger to hold the CPU at the north and south center edges. Align the CPU key (the semi-circle cutout) with the socket key (the notch below the gold color dot on the side of the socket).
Chapter 5: Advanced Serverboard Setup Installing a CPU Heatsink Remove power from the system and unplug the AC power cord from the power supply. Do not apply any thermal grease to the heatsink or the CPU die; the required amount has already been applied.
SUPERSERVER 6026TT-HD/D6 Series User's Manual Installing Memory CAUTION! Exercise extreme care when installing or removing DIMM modules to prevent any possible damage. Memory Support The X8DTT-H+ series motherboard supports up to 192 GB of registered ECC or 48 GB of unbuffered ECC/non-ECC DDR3-1333/1066/800 MHz in 12 DIMM slots (max. of 16 GB of registered ECC and 4 GB of unbuffered memory per DIMM slot.).
Page 41
Chapter 5: Advanced Serverboard Setup DIMM Population Table DIMM DIMMs DIMM Type (Reg.= Speeds (in MHz) Ranks per DIMM Slots per Populated Registered) (any combination; Channel per Channel SR=Single Rank, DR=Dual Rank, QR=Quad Rank) Reg. DDR3 ECC 800,1066,1333 SR or DR Reg.
SUPERSERVER 6026TT-HD/D6 Series User's Manual Due to the memory allocation to system devices, the amount of memory that remains available for operational use will be reduced when 4 GB of RAM is used. The reduction in memory availability is disproportional. Refer to the table below. Possible System Memory Allocation &...
Chapter 5: Advanced Serverboard Setup Connector Defi nitions Front Panel Accessible Add-on Card Header (JF2) The JF2 add-on card header provides front access to the power supply, Serial ATA and Front Panel Control connections for the X8DTT-H Series motherboard. Plug an Add-On card into this header to use the functions indicated above.
Page 46
SUPERSERVER 6026TT-HD/D6 Series User's Manual Fan Header Fan Header Pin Defi nitions The X8DTT-H series motherboard has Pin# Defi nition one fan header on the motherboard. This Ground 4-pin header is backward compatible with +12V traditional 3-pin fans, however, fan speed Tachometer control is only available for 4-pin fans.
Page 47
Chapter 5: Advanced Serverboard Setup Ethernet Ports LAN Ports Pin Defi nitions Two Ethernet ports are located next to Pin# Defi nition Pin# Defi nition USB0/1 on the IO Backplane. In addition, P2V5SB SGND an IPMI Dedicated LAN is located above TD0+ Act LED USB0/1.
Page 48
SUPERSERVER 6026TT-HD/D6 Series User's Manual Serial Ports Serial Port Pin Defi nitions Pin Defi nitions One serial port is included on the serverboard. Pin # Defi nition Pin # Defi nition The COM port is located beside the VGA port. See the table on the right for pin defi ni- tions.
Chapter 5: Advanced Serverboard Setup Jumper Settings Connector To modify the operation of the serverboard, Pins jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function Jumper of the connector. Pin 1 is identifi ed with a square solder pad on the printed circuit board.
Page 50
SUPERSERVER 6026TT-HD/D6 Series User's Manual LAN1/LAN2 Enable/Disable LAN1/2 Enable/Disable Jumper Settings Change the setting of jumper JPL1/JPL2 Jumper Setting Defi nition to enable or disable the LAN1 and LAN2 Pins 1-2 Enabled ports respectively. See the table on the right Pins 2-3 Disabled for jumper settings.
Chapter 5: Advanced Serverboard Setup Onboard Indicators LAN1/LAN2 LEDs LAN1/LAN2 LEDs (Connection Speed The Ethernet ports (located beside the COM Indicator) port) have two LEDs. On each Gb LAN port, LED Color Defi nition one LED indicates activity when blinking No connection or while the other LED may be green, amber or 10 Mb/s...
SUPERSERVER 6026TT-HD/D6 Series User's Manual BMC Activity LED (LE2) A BMC Heartbeat LED is located at LE2 BMC Heartbeat LED on the motherboard. When LE2 is on, BMC is normal BMC (Baseboard Management Controller) is active. See the table at right for more information.
Chapter 5: Advanced Serverboard Setup 5-11 Installing Additional Drivers After you've installed the Windows Operating System, a screen as shown below will appear. You are ready to install software programs and drivers that have not yet been installed. To install these software programs and drivers, click the icons to the right of these items.
The Supero Doctor III program is a web-based management tool that supports remote management capability. It includes Remote and Local Management tools. The local management is called the SD III Client. The Supero Doctor III program included on the CDROM that came with your serverboard allows you to monitor the environment and operations of your system.
Page 55
Chapter 5: Advanced Serverboard Setup Note: SD III Software Revision 1.0 can be downloaded from our Web site at: ftp:// ftp.supermicro.com/utility/Supero_Doctor_III/. You can also download SDIII User's Guide at: http://www.supermicro.com/PRODUCT/Manuals/SDIII/UserGuide.pdf. For Linux, we will still recommend that you use Supero Doctor II. 5-21...
Page 56
SUPERSERVER 6026TT-HD/D6 Series User's Manual Notes 5-22...
Chapter 6: Advanced Chassis Setup Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform main- tenance on the SC827HD-R1400B chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If some steps are unnecessary, skip ahead to the step that follows.
SUPERSERVER 6026TT-HD/D6 Series User's Manual Figure 6-1. Chassis Front View Node A Control Panel Node B Control Panel Hard Drives Figure 6-2. Chassis Rear View Dedicated IPMI LAN Port Dedicated IPMI LAN Port LAN Ports PCI-Express x8 Cards Power Supply LAN Ports PCI-Express x8 Cards USB Ports COM Port VGA Port...
Chapter 6: Advanced Chassis Setup Fan Confi guration In the 2U Twin, each node (serverboard) controls the two fans that reside on its side of the chassis. If the fan speed settings in BIOS are set to different values for each two node, the BIOS setting with the higher fan speed will apply to both.
SUPERSERVER 6026TT-HD/D6 Series User's Manual Hard Drive Installation/Removal Overview The hard drives are mounted in drive carriers to simplify their installation and removal from the chassis. These carriers also help promote proper airfl ow for the system. For this reason, even empty carriers without drives installed must remain in the chassis.
Page 61
Chapter 6: Advanced Chassis Setup Figure 6-3. Removing a Dummy Drive Tray Figure 6-4. Mounting a Hard Drive in a Carrier Hard Drive Drive Carrier Installing/Removing Hot-swap Drives To remove a carrier, push the release button located beside the drive LEDs. Swing the handle fully out and use it to pull the unit straight out (see Figure 6-5).
Page 62
SUPERSERVER 6026TT-HD/D6 Series User's Manual Figure 6-5. Removing a Hard Drive Figure 6-6. Drives and Nodes: Logical Confi guration Note: see Figure 6-1 for the locations of the control panels that are associated with each node.
Chapter 6: Advanced Chassis Setup Figure 6-7. Drive Bay Logical Layout Node A Drives Node B Drives Node Installation/Removal As with any server system, power must be removed from the serverboard when upgrading or installing memory or processors. In the 2U Twin server, the server- boards (nodes) are capable of being hot-swapped from the chassis, allowing one to be powered down for servicing while the other continues operating.
Page 64
SUPERSERVER 6026TT-HD/D6 Series User's Manual Figure 6-8. Removing a System Node...
Chapter 6: Advanced Chassis Setup Installing the Air Shrouds Air Shrouds Air shrouds concentrate airfl ow to maximize fan effi ciency. The SC827 chassis air shrouds do not require screws to set up. Two identical air shrouds are required, one for each serverboard/node. Installing an Air Shroud Confi...
Page 66
SUPERSERVER 6026TT-HD/D6 Series User's Manual Figure 6-9. Removing the Power Supply Release Tab 6-10...
Chapter 7: BIOS Chapter 7 BIOS Introduction This chapter describes the AMI BIOS Setup Utility for the X8DTT-HF+/HIBXF+/ HIBQF+. The AMI ROM BIOS is stored in a Flash EEPROM and can be easily updated. This chapter describes the basic navigation of the AMI BIOS Setup Utility setup screens.
SUPERSERVER 6026TT-HD/D6 Series User's Manual Starting the Setup Utility Normally, the only visible Power-On Self-Test (POST) routine is the memory test. As the memory is being tested, press the <Delete> key to enter the main menu of the AMI BIOS Setup Utility. From the main menu, you can access the other setup screens.
Page 69
Chapter 7: BIOS Day MM/DD/YY format. The time is entered in HH:MM:SS format. (Note: The time is in the 24-hour format. For example, 5:30 P.M. appears as 17:30:00.) Supermicro X8DTT/-F/-IBX/-IBXF/-IBQ/-IBQF BIOS Build Version This item displays the BIOS revision used in your system. BIOS Build Date This item displays the date when this BIOS was completed.
SUPERSERVER 6026TT-HD/D6 Series User's Manual Advanced Setup Confi gurations Use the arrow keys to select Boot Setup and hit <Enter> to access the submenu items: BOOT Features Quick Boot If Enabled, this option will skip certain tests during POST to reduce the time needed for system boot.
Chapter 7: BIOS Hit 'Del' Message Display This feature displays "Press DEL to run Setup" during POST. The options are Enabled and Disabled. Interrupt 19 Capture Interrupt 19 is the software interrupt that handles the boot disk function. When this item is set to Enabled, the ROM BIOS of the host adaptors will "capture"...
Page 72
SUPERSERVER 6026TT-HD/D6 Series User's Manual C1E Support Select Enabled to use the feature of Enhanced Halt State. C1E signifi cantly reduces the CPU's power consumption by reducing the CPU's clock cycle and voltage during a "Halt State." The options are Disabled and Enabled. Hardware Prefetcher (Available when supported by the CPU) If set to Enabled, the hardware pre fetcher will pre fetch streams of data and instruc- tions from the main memory to the L2 cache in the forward or backward manner to...
Chapter 7: BIOS tion and heat dissipation. Please refer to Intel’s web site for detailed information. The options are Disable (Disable GV3) and Enable (Enable GV3). Intel® TurboMode Technology Select Enabled to use the Turbo Mode to boost system performance. The options are Enabled and Disabled.
Page 74
SUPERSERVER 6026TT-HD/D6 Series User's Manual QPI L0s and L1 This enables the QPI power state to low power. L0s and L1 are automatically selected by the motherboard. The options are Disabled and Enabled. Memory Frequency This feature forces a DDR3 frequency slower than what the system has detected. The available options are Auto, Force DDR-800, Force DDR-1066, and Force DDR-1333.
Page 75
Chapter 7: BIOS Throttling - Closed Loop/Throttling - Open Loop Throttling improves reliability and reduces power in the processor by automatic voltage control during processor idle states. Available options are Disabled and Enabled. If Enabled, the following items will appear: Hysteresis Temperature Temperature Hysteresis is the temperature lag (in degrees Celsius) after the set DIMM temperature threshold is reached before Closed Loop Throttling...
Page 76
SUPERSERVER 6026TT-HD/D6 Series User's Manual North Bridge Confi guration This feature allows the user to confi gure the settings for the Intel IOH chip. Crystal Beach/DMA (Direct Memory Access) This feature works with the Intel I/O AT (Acceleration Technology) to accelerate the performance of TOE devices.
Page 77
Chapter 7: BIOS USB 2.0 Controller Select Enabled to activate the onboard USB 2.0 controller. The options are Enabled and Disabled. USB 2.0 Controller Mode This setting allows you to select the USB 2.0 Controller mode. The options are Hi-Speed (480 Mbps) and Full Speed (12 Mbps). BIOS EHCI Hand-Off Select Enabled to enable BIOS Enhanced Host Controller Interface support to provide a workaround solution for an operating system that does not have EHCI...
Page 78
SUPERSERVER 6026TT-HD/D6 Series User's Manual Hot Plug (This feature is available when the option-Enabled is selected) Select Enable to enable the hot plug function for the SATA devices. The options are Enabled and Disabled. SATA#2 Confi guration Selecting Enhanced will set SATA#2 to native SATA mode. The options are Disabled, and Enhanced.
Page 79
Chapter 7: BIOS Select 0 to allow the AMI BIOS to use PIO mode 0. It has a data transfer rate of 3.3 MBs. Select 1 to allow the AMI BIOS to use PIO mode 1. It has a data transfer rate of 5.2 MBs.
Page 80
SUPERSERVER 6026TT-HD/D6 Series User's Manual Select UDMA5 to allow the BIOS to use Ultra DMA mode 5. It has a data transfer rate of 133 MBs. Select UDMA6 to allow the BIOS to use Ultra DMA mode 6. It has a data transfer rate of 133 MBs.
Page 81
Chapter 7: BIOS Load Onboard LAN1 Option ROM/Load Onboard LAN2 Option ROM Select Enabled to enable the onboard LAN1 or LAN2 Option ROM. This is to boot computer using a network interface. The options are Enabled and Disabled. Super IO Device Confi guration Serial Port1 Address/ Serial Port2 Address This option specifi...
SUPERSERVER 6026TT-HD/D6 Series User's Manual Terminal Type This feature allows the user to select the target terminal type for Console Redirec- tion. The options are ANSI, VT100, and VT-UTF8. VT-UTF8 Combo Key Support A terminal keyboard defi nition that provides a way to send commands from a remote console.
Page 83
Chapter 7: BIOS CPU Temperature/System Temperature This feature displays current temperature readings for the CPU and the System. The following items will be displayed for your reference only: CPU Temperature The CPU thermal technology that reports absolute temperatures (Celsius/Fahr- enheit) has been upgraded to a more advanced feature by Intel in its newer processors.
Page 84
SUPERSERVER 6026TT-HD/D6 Series User's Manual User intervention: If the system buzzer and Overheat LED has activated, take action immediately by checking the system fans, chassis ventilation and room temperature to correct any problems. Notes: The system may shut down if it continues for a long period to prevent damage to the CPU.
Page 85
Chapter 7: BIOS APIC ACPI SCI IRQ When this item is set to Enabled, APIC ACPI SCI IRQ is supported by the system. The options are Enabled and Disabled. Headless Mode This feature is used to enable system to function without a keyboard, monitor or mouse attached The options are Enabled and Disabled.
Page 86
SUPERSERVER 6026TT-HD/D6 Series User's Manual View BMC System Event Log This feature displays the BMC System Event Log (SEL). It shows the total num- ber of entries of BMC System Events. To view an event, select an Entry Number and pressing <Enter> to display the information as shown in the screen. •...
Page 87
Chapter 7: BIOS IP Address Source Select the source of this machine's IP address. If Static is selected, you will need to know and enter manually the IP address of this machine below. If DHCP is selected, the BIOS will search for a DHCP (Dynamic Host Confi guration Protocol) server in the network it is attached to, and request the next available IP address.
Page 88
SUPERSERVER 6026TT-HD/D6 Series User's Manual Subnet Mask This item displays the current subnet mask setting for your IPMI connection. Current Subnet Mask in BMC This item displays the current subnet mask used for your IPMI connection. Gateway Address Confi guration Enter the gateway address for this machine.
Chapter 7: BIOS DMI Event Log View Event Log Use this option to view the System Event Log. Mark all events as read This option marks all events as read. The options are OK and Cancel. Clear event log This option clears the Event Log memory of all messages. The options are OK and Cancel.
SUPERSERVER 6026TT-HD/D6 Series User's Manual Password Check This item allows you to check a password after it has been entered. The options are Setup and Always. Boot Sector Virus Protection When Enabled, the AMI BOIS displays a warning when any program (or virus) is- sues a Disk Format command or attempts to write to the boot sector of the hard disk drive.
Page 91
Chapter 7: BIOS Hard Disk Drives This feature allows the user to specify the boot sequence from all available hard disk drives. The settings are Disabled and a list of all hard disk drives that have been detected (i.e., 1st Drive, 2nd Drive, 3rd Drive, etc). •...
SUPERSERVER 6026TT-HD/D6 Series User's Manual Exit Options Select the Exit tab from the AMI BIOS Setup Utility screen to enter the Exit BIOS Setup screen. Save Changes and Exit When you have completed the system confi guration changes, select this option to leave the BIOS Setup Utility and reboot the computer, so the new system con- fi...
Page 93
Chapter 7: BIOS How to Recover the AMIBIOS Image (the Main BIOS Block) An AMIBIOS fl ash chip consists of a boot sector block, and a main BIOS code block (a main BIOS image). The boot sector block contains critical BIOS code, including memory detection and recovery code to be used to fl...
Page 94
SUPERSERVER 6026TT-HD/D6 Series User's Manual Boot Sector Recovery from a Serial Port ("Serial Flash") This process, also known as "Serial Flash," allows the user to use a serial port to load a BIOS image for Boot Sector recovery. This feature is usually used for embed- ded systems that rely on a serial port for remote access and debugging.
Page 95
Chapter 7: BIOS 4. Power on your system and click the <Connect> button in the Hyper Terminal. The terminal screen will display the following messages. 5. Following the instructions given on the screen to update the BIOS. These instructions are also shown below. a.
Page 96
SUPERSERVER 6026TT-HD/D6 Series User's Manual 6. Once you've completed the instructions given, a screen will display to indicate that remote fl ashing is starting and the new BIOS fi le is being uploaded. 7. To use Hyper Terminal to transfer the XModem protocol by using the "Send File"...
Appendix A: BIOS Error Beep Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue the boot-up process.
Page 98
SUPERSERVER 6026TT-HD/D6 Series User's Manual Notes...
Appendix B: Installing Windows Appendix B Installing Windows After all hardware components have been installed, you must fi rst confi gure Intel South Bridge RAID Settings before you install the Windows OS and other software drivers. To confi gure RAID settings, please refer to RAID Confi guration User Guides posted on our web site at www.supermicro.com/support/manuals.
Page 100
SUPERSERVER 6026TT-HD/D6 Series User's Manual B-2 Installing Windows for a Non-RAID System Insert Microsoft's Windows XP/2003 Setup CD in the CD drive and the system will start booting up from CD. Continue with the OS installation. The Windows OS Setup screen will display. From the Windows XP/2003 Setup screen, press the <Enter>...
Appendix C: System Specifi cations Appendix C System Specifi cations Note: unless noted specifi cations apply to a complete system (two serverboards). Processors Four Intel® 5600/5500 Series processors in LGA1366 sockets Note: Please refer to our website for details on supported processors. Chipset Intel 5520/ICH10R BIOS...
Page 102
SUPERSERVER 6026TT-HD/D6 Series User's Manual Serverboard 6026TT-HDTRF/ 6026TT-D6RF: X8DTT-HF+ 6026TT-HDIBXRF/ 6026TT-D6IBXRF: X8DTT-HIBXF+ 6026TT-HDIBQRF/ 6026TT-D6IBQRF: X8DTT-HIBQF+ Dimensions (all): 16.64" (L) x 6.80" (W) (422.66 mm x 172.72 mm) Chassis SC827HD-R1400B (2U Rackmount) Dimensions: (WxHxD) 17.2 x 3.5 x 28.5 in. (437 x 89 x 724 mm) Weight Gross Weight: 85 lbs.
Page 103
Appendix C: System Specifi cations Regulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/- 3-3, CISPR 22 Class A Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11) Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and Canada), CE Marking (Europe) California Best Management Practices Regulations for Perchlorate Materials:...
Page 104
SUPERSERVER 6026TT-HD/D6 Series User's Manual (continued from front) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency com- munication devices or other critical systems whose failure to perform be reasonably expected to result in signifi...