Serial Ports; Power Fail Header; Fan Headers - Supero SuperServer 6024H-TR User Manual

Supermicro superserver 6024h-tr servers: user guide
Table of Contents

Advertisement

S
UPERSERVER 6024H-TR/6024H-T User's Manual

Serial Ports

The COM1 serial port is located beside
the mouse port. COM2 is a header on
the serverboard (see serverboard
layout for location). See the table on
the right for pin defi nitions.

Power Fail Header

Connect a cable from your power sup-
ply to the Power Fail header to provide
you with warning of a power supply
failure. The warning signal is passed
through the PWR_LED pin to indicate
a power failure. See the table on the
right for pin defi nitions.

Fan Headers

The X6DHT-G has eight fan headers,
designated Fan1 through Fan8. Fan
speed is controlled via Thermal Man-
agement with a BIOS setting. See the
table on the right for pin defi nitions.
Note: Fans 5-8 are 4-pin fans. Pins
1-3 of the fan headers are backward
compatible with traditional 3-pin fans.
The onboard fan speed is controlled
by a BIOS setting. When using a
Thermal Management setting, use
all 3-pin fans or all 4-pin fans on the
motherboard. Do not use 3-pin fans
and 4-pin fans together.
Serial Port Pin Defi nitions
(COM1/COM2)
Pin #
Defi nition
1
CD
2
RD
3
TD
4
DTR
5
Ground
Note: Pin 10 is included on the header but not on
the port. NC indicates no connection.
Power Fail Header
Pin Defi nitions (JP9)
Pin#
1
2
3
4
Note: This feature is only available when using
redundant Supermicro power supplies.
Fan Header
Pin Defi nitions
Pin#
1
2
3
4
5-14
Pin #
Defi nition
6
DSR
7
RTS
8
CTS
9
RI
10
NC
Defi nition
P/S 1 Fail Signal
P/S 2 Fail Signal
P/S 3 Fail Signal
Reset (from MB)
(Fan1-8)
Defi nition
Ground (Black)
+12V (Red)
Tachometer
PWM Control