5.4
Ignition pilot burner
For correct working, set the gas pressure (A - Fig. 19) according
to the air pressure (B - Fig. 19)
Key (Fig. 20)
1
Gas pressure (mbar)
2
Thermal power (kW)
3
3
Air flow (m
/h)
4
Combustion stability field
5
Ideal line
5.4.1
Pilot burner disassembly
To dismantle the pilot burner proceed as follows:
turn off the gas supply valve A;
disconnect the air and gas hoses from the pilot burner B-C;
remove the socket D;
loosen nut E of the pilot clamp.
Slide out the pilot burner.
5.4.2
Pilot burner introduction
To refit the pilot burner in its seat, reassemble following the pre-
viously described steps in reverse order, positioning all compo-
nents as they were originally assembled.
During the introduction, pay particular attention that the pilot in-
serts into the support 1)(Fig. 22).
20188797
Start-up, calibration and operation of the burner
20161941
24
GB
20161978
Fig. 19
Fig. 20
20162046
Fig. 21
20162117
Fig. 22