Technical Specifications - Seitron CHEMIST 600 BE GREEN Use And Maintenance

Combustion analyzer
Table of Contents

Advertisement

7.0

TECHNICAL SPECIFICATIONS

7.1 Technical features
Power supply:
Battery charger:
Charging time:
Instrument working time:
——————————————————————————————————————————————————
Display:
——————————————————————————————————————————————————
Connectivity:
Communication port:
®
Bluetooth
:
——————————————————————————————————————————————————
Autozero:
Dilution:
——————————————————————————————————————————————————
Gas measurement sensors:
Programmed fuels:
——————————————————————————————————————————————————
Self-diagnosis:
Temperature measurement:
Measurement of ambient temp.:
——————————————————————————————————————————————————
Internal data memory:
User data:
Print header:
——————————————————————————————————————————————————
Suction pump:
Measurement of flow:
Condensate trap:
Line filter:
Smoke:
Leak test:
Condensing boiler efficiency:
Li-Ion battery pack with internal protection circuit, rechargeable.
External 5Vdc 2A battery charger with female A-type USB connector +
connection to the device with the same serial communication cable
supplied.
5 hours to charge from 0% to 90% (6 hours for 100%). The device can
also be charged by connecting it to the PC, the device must be turned off,
the charging time depends on the output current from the PC and may be
more than 12 hours.
12 hours of non-stop operation (excluding printing).
4.3" TFT 272x480 pixels graphic color with backlight
USB connector type B.
Class 1. Communication distance <100 meters (in open field)
Automatic autozero cycle with the probe not inserted in the chimney.
Widens the CO sensor measurement range up to 100.000ppm (10.00%).
Programmable as simple protection of the CO sensor with the intervention
level set by the user.
Default triggering threshold at 1500 ppm.
Up to 6 configurable sensors: electrochemical, NDIR (single cell) and
pellistor.
15 factory default plus 32 user-programmable.
All the functions and internal functions are checked and anomalies
signalled.
Double K thermocouple input with mini connector (ASTM E 1684-96 ) to
measure differential temperature (supply and return)
Via internal sensor or T2 thermocouple input with remote probe.
2000 complete data analyses, time and name of the customer can be
stored.
8 programmable user names.
6 lines x 24 characters user-customized.
1.0 l/min heads at the flue up to 135mbar.
Internal sensor to measure the flow of the pump.
Outside the instrument.
With replaceable cartridge, 99% efficient with 20um particles (inside the
condensate trap).
Using an external hand pump; it is possible to enter and print the smoke
index.
Gas pipes tested for leaks with separate printout of the result, by means of
the attachment AACKT02, according to UNI 7129 (new systems) and UNI
11137: 2019 (existing systems), with automatic calculation of pipe volume.
Automatic recognition of the condensing boiler, with calculation and
printout of efficiency (>100%) on the LHV (Lower Heating Value) in
accordance with UNI10389-1.
18
K400000000SE 041891 010823