2.0

SAFETY

2.1 Safety check

 Use the product according to what is described in chapter "Intended purpose".
 During the instrument operation, comply with the current standards.
 Do not use the instrument if damaged on the outer cover, on the power supply plug or on the cables.
 Do not take measures on non-isolated components / voltage conductors.
 Keep the instrument away from solvents.
 For the maintenance of the instrument, strictly comply with what's described in this manual at the
"Maintenance" chapter.
 All the interventions not specified in this manual, may be performed exclusively by Seitron assistance centers.
Otherwise, Seitron declines every responsibility about the normal operation of the instrument and on the
validity of the several homologations.
2.2 Intended purpose
This chapter describes the areas of application for which the CHEMIST 600 BE GREEN is intended.
Using the CHEMIST 600 BE GREEN in other application areas is on the risk of the operator and the
manufacturer assumes no responsibility and liability for loss, damage or costs which could be a result. It is
mandatory to read and pay attention to the operating/maintenance manual.
All products of the series CHEMIST 600 BE GREEN are handheld measuring devices in professional flue gas
analysis for:
Small furnaces (burning oil, gas, wood, coal)
Low-temperature and condensing boilers
Gas heaters
Due to other configuration with electrochemical cells it is possible to use the measuring instrument in following
application area:
Service engineers/mechanics of burner/boiler manufacturers
Service industrial combustion plants
Additional functions of the measuring instrument:
Flue gas analysis according 1. BImSchV or qA-mean value (selectable)
Calculating of stack heat loss and efficiency
CO- and NO environment measurement
Tightness test
Store Smoke value, calculating mean value
Measuring differential pressure
Draft measurement

2.3 Improper use of the product

The use of CHEMIST 600 BE GREEN in application areas other than those specified in
use of the product"
is to be considered at the operator's risk and the manufacturer assumes no responsibility for
the loss damage or costs that may result. It is compulsory to read and pay attention to the instructions in this use
and maintenance manual.
CHEMIST 600 BE GREEN should not be used:
For continuous measurements > 1h
As safety alarm instrument

2.4 Precautions for the usage of the Li-Ion battery package

Pay attention while handling the battery package inside the instrument; a wrong or improper usage may lead to
heavy physical injuries and/or damages:
• Do not create a short circuit: make sure that the terminals are not in contact with metal or other conductive
materials during transportation or storage.
• Do not apply with inverted polarities.
• Do not make the batteries come in contact with liquid substances.
• Do not burn the batteries nor expose to temperature higher than 140 °F (60°C).
• Do not try to disassemble the battery.
• Do not cause collisions or pierce the batteries. Improper use can cause damages and internal short circuits not
always externally visible. If the battery package has fallen or has been hit with an hard surface, regardless the
external shell condition:
• Stop operation;
• Dispose of the battery in compliance with the disposal instructions;
• Do not use batteries with leaks or damages.
• Charge the batteries only inside the instrument.
• If a malfunction occurs or if over heating signs occur, immediately remove the battery package from the
instrument. Warning: the battery may be hot.