8.0 USING THE FLUE GAS ANALYZER

8.1

Preliminary operations

Remove the instrument from its packing and check it for damage. Make sure that the content corresponds to the
items ordered. If signs of tampering or damage are noticed, notify the SEITRON service center or distributor
immediately and keep the original packing. A label at the rear of the analyzer bears the serial number. This serial
number should always be stated when requesting technical assistance, spare parts or clarification on the product
or its use.
Seitron maintains an updated database for each and every instrument.
Before using for the first time we recommend you charge the batteries completely.
8.2
WARNING
 Use the instrument with an ambient temperature between -5 and +45°C.
IF THE INSTRUMENT HAS BEEN KEPT AT VERY LOW TEMPERATURES (BELOW
OPERATING TEMPERATURES) WE SUGGEST WAITING A WHILE (1 HOUR) BEFORE
SWITCHING IT ON TO HELP THE SYSTEM'S THERMAL BALANCE AND TO PREVENT
CONDENSATE FORMING IN THE PNEUMATIC CIRCUIT.
 When it has finished being used, before turning the instrument off remove the probe and let is aspirate ambient
clean air for at least 5 minutes to purge the pneumatic path from all traces of gas.
 Do not use the instrument if the filters are clogged or damp.
 Before putting the measuring probe back in its case after use, make sure it is has cooled down enough and
there is no condensate in the tube. It might be necessary to periodically disconnect the filter and the
condensate separator and blow compressed air inside the tube to eliminate all residues.
 Remember to have the instrument checked and calibrated once a year in order to comply with the existing
standards.
IF ENABLED BY FACTORY OR THE ASSISTANCE CENTER, FROM 30 DAYS PRIOR TO
THE CALIBRATION TO EXPIRE, THE DISPLAY WILL SHOW A MESSAGE TO REMIND THE
USER THAT THE INSTRUMENT HAS TO BE SENT TO THE ASSISTANCE CENTER.
Example:
Reminder
Calibration
Annual calibration reminder.
Expiration date: 15/07/19
F1: Info service
Press
F2: Ignore
and
F3: Ignore forever
hold for
a few
seconds
F1
F2
CONTEXT KEY
F1
F2
F3
15/01/14
10:00
F3
FUNCTION
Displays the information about the assistance center.
Ignores temporarily the message. Next time the instrument will be turned
on, the remainder will be displayed again.
Ignores permanently the message.