Cxhy Sensor For Measurement Of The Unburnt Hydrocarbons; Installing The Cxhy Sensor - Seitron CHEMIST 600 BE GREEN Use And Maintenance

Combustion analyzer
Table of Contents

Advertisement

15.6 CxHy sensor for measurement of the unburnt hydrocarbons

The unburnt hydrocarbons are chemicals produced by an incomplete combustion of molecules (hydrocarbons)
made of Carbon and Hydrogen.
These are usually named as HC or (better) CxHy: when this is filled with the actual values for the number of C
and H atoms, the actual type of fuel is exactly defined. In case of Methane, as an example, the correct formula is
CH4. In the following table is shown the cross sensitivity of the CxHy sensor when exposed to fuels different from
Methane (CH4), assumed as 1.00.
GAS / VAPOR
Ethanol
Iso-Butane
Methane
Methanol
n-Butane
n-Heptane
n-Hexane
Propane
Calculation example:
Type of gas:
Relative response:
Gain adjustment:
Reading value (related to methane):
Value = reading value x gain adjustment
Example:
1.34 x 1.67 = 2.24
WARNING
Gases that contain acidic or silicone compounds (HMDS) can irreversibly damage the sensor.
15.6.1

Installing the CxHy sensor

When the CxHy (position S1 - S6) is mounted in the instrument, it is mandatory to configure the autozero by set-
ting it at 180 seconds, in order to allow for a proper pre-heating of the sensor itself.
The instrument battery life, once the CxHy is installed, lasts 10 hours, provided no printing is made.
Configuration→Analysis→Autozero
15/01/14
10:00
Configuration
Autozero
Autozero
60
s
Purging
0
s
O
RELATIVE RESPONSE
(with respect to Methane)
0.75
0.60
1.00
1.00
0.60
0.45
0.50
0.70
iso-butane
0.6
1.67
1.34
(SEE SECTION
15/01/14
10:00
Configuration
Autozero
Autozero
060
s
Purging
0
s
O
OK
GAIN ADJUSTMENT
11.2.6)
15/01/14
Configuration
Autozero
Autozero
s
Purging
s
O
OK
163
1.33
1.67
1.00
1.00
1.67
2.22
2.00
1.43
10:00
Configuration
Autozero
Autozero
180
s
Purging
0
s
OK
O
K400000000SE 041891 010823
15/01/14
10:00
180
0

Advertisement

Table of Contents
loading

Table of Contents