8.3 Analyzer power supply

The instrument contains a high-capacity Li-Ion rechargeable battery.
The battery feeds the instrument, built-in printer and any other probes or remote devices that may be connected.
The instrument runs for approximately 18 hours if the printer is not used. Should the battery be too low to effect
the necessary measurements, the instrument can be hooked up to the mains via the power pack provided,
allowing operations (and analysis) to proceed. The battery will be recharged whilst the instrument is being used.
The battery charging cycle takes up to 3 hours for a complete charge and finishes automatically.
WARNING: If the instrument is not going to be used for a long time (e.g. summer) it is advised to store it
after a complete charging cycle; furthermore, perform a complete charging cycle once every 4 months.
8.3.1

Checking and replacing the batteries

The state of the internal battery can be displayed during the auto-calibration of the device and possibly later via
the information menu.
In the menu, the remaining battery power is displayed.
If battery charge appears to be low, let it discharge completely and then carry out a full 100% charge cycle by
connecting the instrument to the power pack for 3 hours.
If the problem persists, replace the battery pack with a SEITRON original or contact the SERVICE CENTER to
carry out the necessary repairs.
The average life of the battery pack is 500 charging/discharging cycles. To exploit this characteristic to the full it
is advisable to always use the instrument powered by the internal batteries and to charge it only when it gives the
battery flat message.
THE INSTRUMENT IS SHIPPED WITH A BATTERY LEVEL LOWER THAN 30% AS
REQUIRED BY CURRENT AIR TRANSPORTATION STANDARDS. BEFORE USE PERFORM
A COMPLETE CHARGING CYCLE OF 8 HOURS.
IT IS ADVISABLE TO CHARGE THE BATTERY AT AN AMBIENT TEMPERATURE RANGING
BETWEEN 10°C AND 30°C.
The instrument can be left in stock for a period of time depending on the charging level of the battery; below there
is a table showing the correlation between stock time and charging level.
BATTERY LEVEL
100%
75%
50%
25%
8.3.2

Use with external power pack

The instrument can work with the batteries fully discharged by connecting the external power pack provided.
THE POWER SUPPLY/BATTERY CHARGER IS A SWITCHING TYPE ONE.
THE APPLICABLE INPUT VOLTAGE RANGES BETWEEN 90Vac AND 264Vac.
INPUT FREQUENCY: 50-60Hz.
THE LOW VOLTAGE OUTPUT IS 5 VOLT WITH AN OUTPUT CURRENT GREATER THAN
1.5A.
LOW VOLTAGE POWER CONNECTOR: A-TYPE USB CONNECTOR + CONNECTION CABLE WITH B-
TYPE PLUG.
8.4

QR Code generation

By pushing at the same time the buttons
code in order to download the data of the performed measures, having previously installed the special Seitron
App "SEITRON SMART ANALYSIS" downloadable from the Google play store or Apple iOS App store.
Minimum requirements for the "SEITRON SMART ANALYSIS" App installation
Operative systems:
THE INSTRUMENT GENERATES THE QR CODE ONLY IF THE INTERACTIVE FUNCTION
"
" IS SHOWN ON THE DISPLAY.
+
Android from version 4.1
Apple (iOS)
STOCK TIME
110 days
80 days
45 days
30 days
OK
, the instrument generates and shows on the display a QR
23
K400000000SE 041891 010823

Advertisement

Table of Contents
loading

Table of Contents