Filter Pump
In the example below, a variable speed pump which was named "vsp" has been configured to be
used with the Pool in the Configuration Wizard. Touching the "vsp" button in the Features Screen will
bring you to a pump Control Screen which will let you manually turn on/off the pump, set a schedule,
set a speed, apply a countdown timer and view the status. Single speed and two speed pumps will
have a similar Control Screen.
vsp
pH
heat/cool
cleaner
POOL
features
Pool Features Screen
Turn On / Turn Off - Slide
this switch manually to turn
on/off the pump. This will
override any schedules or timer
settings.
Change Speed - Manually
select the desired speed. This
will not be shown for single
speed pumps. Low, Med, and
High are fixed speeds. The
Custom button will bring you
to a screen that allows you to
select a speed based on per-
centage or RPM (determined
during configuration).
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
1 / 2
alarm
light row
uclights
chlorinator
Status of Equipment - This is an indicator
only. When lit up and in motion (shown be-
low), the equipment is active. When grayed
out and stationary, the equipment is off.
ON
LOW
MED
POOL
vsp pump
ON
LOW
MED
POOL
vsp pump
Pump Control Screen
ON
HIGH
CUSTOM
ON
HIGH
CUSTOM
Set Schedule - Touch
this button to add/delete a
schedule for the filter pump
or to enable/disable an
existing schedule.
Countdown Timer - Touch
this button to set a count-
down timer for the filter
pump.
Diagnostics - Touch this
button to view the filter
pump's diagnostics. This
option only appears for vari-
able speed pumps.
8