• Replace damaged, broken, cracked, missing, or unsecured suction outlet compo- nents immediately. • In addition, two or more suction outlets per pump installed in accordance with latest ASME, APSP Standards and CPSC guidelines, follow all applicable National, State, and Local codes. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 3
To reduce the risk of electric shock, do NOT use an extension cord to connect unit to electric supply. Provide USE ONLY HAYWARD GENUINE REPLACEMENT PARTS USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 4
A permanently-installed pool is constructed in or on the ground in a building such that it cannot be readily disassembled for storage. A storable pool can be readily disassembled for storage and reassembled to its original integrity. SAVE THESE INSTRUCTIONS USE ONLY HAYWARD GENUINE REPLACEMENT PARTS USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
This OmniPL Retrofit Kit is compatible with all “P-4”, “PS-4”, and “PS-8” units. The HLPROUPG is not compatible with “PS-16” although two kits could be installed (one in PS-16, one in the Expansion unit) to manage one pool.
Page 6
The current control’s configured equipment, timers and settings will be lost after replacing the main printed circuit board (mainboard) with the OmniPL Retrofit Kit mainboard. It’s important to capture all of this information before starting the installation. A worksheet is provided on the following pages to record all current settings.
Page 7
NOTE: The configuration menu automatically “locks” after 2 minutes of no buttons being pressed to prevent unauthorized people from changing the control logic inadvertently and possibly damaging the pool equipment or causing a “call back” to fix the configuration. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
C C H H E E C C K K M M E E N N U U S S Y Y S S T T E E M M Remove local display keypad ProLogic or AquaPlus Mainboard Local display keypad removed USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 11
Transformer wiring - These blue, purple, white and gray primary transformer wires will be connected to a wiring harness that plugs into the OmniPL mainboard. Relay wiring - this wiring will plug into an identical connector on the OmniPL mainboard. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 12
Wago lever connectors on a wiring harness that plugs into the OmniPL mainboard. Remove old Mainboard and install new OmniPL Retrofit Kit Mainboard With all the wires disconnected from the old mainboard, unscrew the two fasteners located at the bottom of the mainboard and then remove. Position the new OmniPL mainboard in its place. The...
Page 13
Tighten the two screws to secure the OmniPL mainboard. The local display will not be reused. Wiring the OmniPL Mainboard ECOMMAND: Because the ECOMMAND did not require a transformer, a Hayward GLXS3PLXFMR transformer must be purchased separately to power the OmniPL mainboard. Refer to the mounting instructions included with the GLXS3PLXFMR.
Page 14
Connect one end to the Controller and the other to an available LAN port (not WAN) on the home router or access point as shown. If using wireless, a 2.4GHz connection to the LAN port router is required. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
ID. Because the control was previously wired, take this time to go through each connection and fill out the table. Refer to the graphic below for the physical location of these connections. HVR1 HVR2 HVR3 HVR4 HVR5 HVR6 HVR7 HVR8 When using Optional Smart Relays USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Wizard at a later time to make changes. Navigation The Configuration Wizard has been designed to be intuitive allowing most users the ability to navi- gate with little instruction. On the following page, a list of commonly used buttons are explained. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 17
Configuration Wizard and select “Edit”. The initial configuration settings will be retained and you’ll have an opportunity to make changes or additions. Be sure to save your configuration when exiting. See page 36 for a Quick Edit Guide. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 18
“Shared Heaters”. If you have dual equipment with shared heaters, this can be configured from the second Body of Water’s configuration menu. See page 31 for more information regarding Shared Equipment in the second Body of Water configuration menu. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 19
Filter Pump Off for Valve Change? When Yes is selected, the pump will shut off for 35 seconds whenever the valve(s) change position. Flow Monitoring Enabled? Requires use of a Hayward flow switch. This fea- ture will help protect the filter pump from damage due to no flow. When Yes is selected, the OmniPL will monitor the state of water flow when the filter pump is on.
Page 20
If VSP is selected: Which Hayward Unique Address? If using a VSP, you’ll be asked what is the Hayward Unique Address (HUA). If a value is already shown in the box, advance to the next screen. If no value is shown, selecting the box will bring you to a table showing all detected devices.
Page 21
OmniLogic remote control capability connected to your OmniLogic and pow- ered on. Select “Yes” if you would like to configure this heater now or “No” if you would like to configure a different heater. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 22
If Yes is selected: Which Hayward Unique Address? Select the HUA of the Smart Heater that you would like to configure. Name Heater Select the box, then type the desired name for your heater. This name will be used when referring to this particular heater.
Page 23
Minimum Operation Speed? For variable speed pumps, select the lowest pump speed that is allowed while heating. Set a speed that will ensure that there will be sufficient flow for the heater to operate properly. For two speed USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 24
Does Solar Requre the Filter Pump to Prime When it First Turns On? If Yes is selected, the filter pump will turn on in high speed for 3 minutes to circulate water to the solar panels when the heater is activated. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 25
Do you have a Sense & Dispense Module? Select Yes if a Hayward HL-CHEM (sold separately) is connected to the OmniPL.
Page 26
Unique Address. If multiple components are detected, the OmniPL will show a table of devices and prompt you to select the proper device. Which Hayward Unique Address? If a Hayward Unique Address (HUA) is already shown in the box, touch the Advance button. If no address is shown, selecting the box will bring you to a table showing all detected Sense and Dispense devices.
Page 27
Do You Have a Salt Water Chlorine Generator? (requires a connected Hay- ward TurboCell). If Yes is selected: Type of Cell? Select the type of Hayward TurboCell that is installed in your system. Where is the Cell Located? If an entry is already shown in the box, touch the Advance button.
Page 28
If VSP is selected: Which Hayward Unique Address? If using a VSP for your cleaner pump, you’ll be asked what is the Hayward Unique Address (HUA). If a value is already shown in the box, advance to the next screen. If...
Page 29
2 water features; one for the pool Body of Water and one for the spa Body of Water, you would answer “1” to this question. If “1”or more is selected: Select and Configure a Water Feature At this screen you can add, delete and configure USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 30
If VSP is selected: Which Hayward Unique Address? If using a VSP for your water feature pump, you’ll be asked what is the Hayward Unique Address (HUA). If a value is already shown in the box, advance to the next screen.
Page 31
The speed will change at the next scheduled interval. Do You Want to Configure Any Lights? Select yes if you are using any type of pool or spa lights. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 32
If so, the OmniPL will turn this pump on when the accessory is scheduled to run. If Yes is selected: What Type? Select the type of pump used. The choices are Single Speed, Two Speed and VSP. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 33
If VSP is selected: Which Hayward Unique Address? If using a VSP for your accesso- ry pump, you’ll be asked what is the Hayward Unique Address (HUA). If a value is already shown in the box, advance to the next screen. If no value is shown, selecting the box will bring you to a table showing all detected devices.
Page 34
Are any of Body of Water 2’s heaters shared with Body of Water 1? If Yes is selected: Which body of water is heated in the event that both are running? Select the Body of USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 35
(typically FLOW SWITCH 1) and touch the Done button. The sensor connection should now be shown in the box and you can advance to the next screen to continue configuration. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 36
WaterBowl light, the Flicker feature will only be available if the light is set to Omni- Direct mode. How Many Accessories are in the Backyard? Select the number of accessories that will be used for the backyard. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 37
OmniPL. The affected equipment will activate/deactivate depending on the state of the monitored sensor. For flow switch sensors, affected USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 38
Some or all of these options may not appear if you don’t have a variable speed pump, heater or if not using chlorination. An alternative to this interlock is using a Theme to Sensor interlock. Create a Theme using desired settings when the pool cover is USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 39
Home - Touch this button to quickly jump back to the Quick Edit Main Menu Screen to save your changes. This button appears at the end of every configuration pathway. Back - Touch this button to go back to the previous set of configurable items. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 40
Type - Change the type of Filter Pump that is configured (Single Speed, 2-Speed, or VSP) HUA - Match the HUA (Hayward Unique Address) to the configured Filter Pump. This option only appears if the Filter Pump is configured as a Variable Speed Pump.
Page 41
These options are as follows: Name - Rename the heater/chiller to whatever name you desire. HUA - Select the HUA of the Smart Heater. This option only appears if a Smart USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 42
Chemical Type - Select the type of chemical that is being dispensed (acid or pH Dispensers - Configure the pH dispense unit. pH Timeout - Choose the pH timeout time. pH Extend - Select whether you want pH extend enabled for this Body of Water. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 43
Pump - Configure the cleaner pump, if used. Relay - Select the relay that the cleaner is wired to. This option only appears if the cleaner does not have an associated pump configured. Valve - Configure the cleaner valve, if used. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 44
Priming - Select whether you want the water feature pump to prime and the desired duration. This option is only available if the water feature pump is con- figured as a 2-Speed or Variable Speed Pump. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 45
Configuration Wizard portion of this manual. Select an Accessory - Once you select an accessory, all of the options for that ac- cessory will appear on the next screen. These options are as follows: USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 46
Configuration Wizard portion of this manual. Select an Existing Group of Lights - Once you select a group of existing lights, all of the options for those lights will appear on the next screen. These options are as follows: USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 47
Select a Sensor - Once you select a sensor, all of the options for that sensor will appear on the next screen. These options are as follows: Name - Rename the sensor to whatever name is desired. Location - Select the location that the sensor is wired to. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 48
Configuration Wizard. If No is selected - Choose an option below: External Wireless - Make this selection when setting up a Hayward HLWLAN. Note that a 2.4GHz connection to the router is required. Once the system is done running through the diagnostics, press the check mark to continue to the next section of the Configuration Wizard.
Page 49
Themes. These Themes had to have been defined prior to configuring the Aux buttons. Select the desired Theme that you want to assign to the Aux button Unconfigured - If set to “Unconfigured”, the Aux button will have no function. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 50
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Aqua Plus and SwimPure chlorination products to be free of defects in materials and workman- ship, under normal use and service, for a period of three (3) years. Hayward also warrants its Aqua Trol chlorination products to be free of defects in materials and workmanship, under normal use and service for a period of one (1) year.