84
Menu items
Setting option 1
Foot Press.,
Off
Sewing foot
linear
pressure
 p. 87
Max. Speed,
Off
Speed
 p. 87
linear
Overview of settings modes
The material thickness can be identified in various modes and
responded to depending on the setting. This general explanation
can be applied to the following specific parameters.
Setting mode
Description
In the linear setting, the size of the parameter
linear
increases or decreases steadily as the material
thickness increases. The increase/decrease in the
parameter depends on the limits set for the minimum
and maximum material thickness.
If a certain material thickness is exceeded, the
2.OnOff
nd
2
thickness then falls below this level again, it switches
to the base value for the parameter.
If a certain material thickness is exceeded, the
2.On
nd
2
thickness then falls below this level again, it DOES
NOT switch to the base value for the parameter.
Only after finishing the seam by cutting the thread is
the base value for the parameter set again.
Operating Instructions 868-M PREMIUM - 02.0 - 01/2018
value of the parameter is activated. If the material
value of the parameter is activated. If the material
Programming
Setting option 2
Foot Press.
ThickMin
ThickMax
Max. Speed
ThickMin
ThickMax