Figure 111 Clustering Management Configuration

The following table describes the labels in this screen.

Table 79 Clustering Management Configuration

LABEL
Clustering Manager
Active
Name
VID
220
DESCRIPTION
Select Active to have this switch become the cluster manager switch. A cluster
can only have one manager. Other (directly connected) switches that are set to
be cluster managers will not be visible in the Clustering Candidates list. If a
switch that was previously a cluster member is later set to become a cluster
manager, then its Status is displayed as Error in the Cluster Management
Status screen and a warning icon (
below.
Type a name to identify the Clustering Manager. You may use up to 32
printable characters (spaces are allowed).
This is the VLAN ID and is only applicable if the switch is set to 802.1Q VLAN.
All switches must be directly connected and in the same VLAN group to belong
to the same cluster. Switches that are not in the same VLAN group are not
visible in the Clustering Candidates list. This field is ignored if the Clustering
Manager is using Port-based VLAN.
) appears in the member summary list