M0087369-08
Note: Fuel return line (11) may need to be removed
to prime the fuel system.
5. Operate the fuel transfer pump. When fuel free
from air flows from the connections tighten the
connecting bolt. Stop the transfer pump.
6. The engine should now be able to start. Operate
the starting motor to start the engine.
Note: Do not operate the starting motor for more than
15 seconds. If the engine does not start after 15
seconds, stop and wait for 30 seconds before trying
again.
Fuel System Primary Filter -
Replace
Fuel leaked or spilled onto hot surfaces or electri-
cal components can cause a fire. To help prevent
possible injury, turn the start switch off when
changing fuel filters or water separator elements.
Clean up fuel spills immediately.
Ensure that the engine is stopped before any servic-
ing or repair is performed.
Remove the Element
1. Turn the fuel supply valve (if equipped) to the OFF
position before performing this maintenance.
2. Place a suitable container under the water
separator in order to catch any fuel that might spill.
Clean up any spilled fuel. Clean the outside body
of the filter assembly.
Copyright of Perkins Engine Company Limited. NOT FOR REPRINTING OR RESALE
i05337705
NOTICE
Fuel System Primary Filter - Replace
Illustration 79
Typical example
3. Remove the filter bowl (4) from the fuel filter base
(1).
4. Remove the O-ring seal (3). Discard the O-ring
seal.
5. Remove the filter element (2) from the fuel filter
base (1). Discard the filter element (2).
97
Maintenance Section
g03381282