Perkins 402J-05 Operation And Maintenance Manual page 54

Operation and maintenance manual
Table of Contents

Advertisement

54
Maintenance Section
Fluid Recommendations
For a water analysis, consult one of the following
sources:
• Local water utility company
• Agricultural agent
• Independent laboratory
Additives
Additives help to protect the metal surfaces of the
cooling system. A lack of coolant additives or
insufficient amounts of additives enable the following
conditions to occur:
• Corrosion
• Formation of mineral deposits
• Rust
• Scale
• Foaming of the coolant
Many additives are depleted during engine operation.
These additives must be replaced periodically.
Additives must be added at the correct concentration.
Over concentration of additives can cause the
inhibitors to drop out-of-solution. The deposits can
enable the following problems to occur:
• Formation of gel compounds
• Reduction of heat transfer
• Leakage of the water pump seal
• Plugging of radiators, coolers, and small passages
Glycol
Glycol in the coolant helps to provide protection
against the following conditions:
• Boiling
• Freezing
• Cavitation of the water pump
For optimum performance, Perkins recommends a
1:1 mixture of a water/glycol solution.
Note: Use a mixture that will provide protection
against the lowest ambient temperature.
Note: 100 percent pure glycol will freeze at a
temperature of −13 °C (8.6 °F).
Copyright of Perkins Engine Company Limited. NOT FOR REPRINTING OR RESALE
Most conventional antifreezes use ethylene glycol.
Propylene glycol may also be used. In a 1:1 mixture
with water, ethylene and propylene glycol provide
similar protection against freezing and boiling. Refer
to Table 27 and refer to table 28 .
Table 27
Ethylene Glycol
Concentration
50 Percent
60 Percent
NOTICE
Do not use propylene glycol in concentrations that
exceed 50 percent glycol because of the reduced
heat transfer capability of propylene glycol. Use ethyl-
ene glycol in conditions that require additional protec-
tion against boiling or freezing.
Table 28
Propylene Glycol
Concentration
50 Percent
To check the concentration of glycol in the coolant,
measure the specific gravity of the coolant.
Coolant Recommendations
• ELC
• SCA
Supplement Coolant Additive
• ASTM
American Society for Testing and
Materials
The following two coolants are used in Perkins diesel
engines:
Preferred – Perkins ELC
Acceptable – A commercial heavy-duty antifreeze
that meets "ASTM D6210" specifications
NOTICE
The Perkins industrial engines must be operated
with a 1:1 mixture of water and glycol.
NOTICE
Do not use a commercial coolant/antifreeze that only
meets the ASTM D3306 specification. This type of
coolant/antifreeze is made for light automotive
applications.
M0087369-08
Freeze Protection
−36 °C (−33 °F)
−51 °C (−60 °F)
Freeze Protection
−29 °C (−20 °F)
Extended Life Coolant