Omron ZS-DSU41 User Manual page 92

Smart sensors data storage unit
Hide thumbs Also See for ZS-DSU41:
Table of Contents

Advertisement

Section5
Multi-point Simultaneous Logging
First of all, set the following to the ZS-MDC. For details on operation and setup methods,
refer to the User's Manual for the ZS-MDC.
SEL CH
TASK1
OPERA-
TION
ZS-DSU settings
FUN Mode-[LOGING]-[SOURCE]-[SourceA]
1.
Select the source to save data from.
Set the following details to sourceA:
SELECT
SAVE
LABEL
Set [Input B] to [Input D] in the same way to
[SourceB] to [SourceD].
Set [TASK1] to [SourceE].
FUN Mode-[LOGING]-[TRIGGER]-[START]-[I/O]
2.
Set the start trigger.
SOURCE
I/O SEL
ACTIVE
FUN Mode-[LOGING]-[TRIGGER]-[END]-[QUANT]
3.
Set the number of data points to use as the end
trigger to one point.
ZS-DSU
5-6
User's Manual
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Setting item
Input A
Input B
Input C
Input D
Expression type
: Input A
: ON
: (any letters)
: SourceA
: IN0
: OFF→ ON
Setting
2CH
3CH
4CH
5CH
MAX-MIN (all input A to D are valid)
1
SourceA
3
SourceC
1
SOURCE
3
ACTIVE
POINT
2
SourceB
2
I/O SEL
4
DELY
:
000001
DIG
VAL
SETOK

Advertisement